Design optimization of a mechanical heart valve for reducing valve thrombogenicity-A case study with ATS valve.

نویسندگان

  • Yared Alemu
  • Gaurav Girdhar
  • Michalis Xenos
  • Jawaad Sheriff
  • Jolyon Jesty
  • Shmuel Einav
  • Danny Bluestein
چکیده

Patients implanted with mechanical heart valves (MHV) or with ventricular assist devices that use MHV require mandatory lifelong anticoagulation for secondary stroke prevention. We recently developed a novel Device Thrombogenicity Emulator (DTE) methodology that interfaces numerical and experimental approaches to optimize the thrombogenic performance of the device and reduce the bleeding risk associated with anticoagulation therapy. Device Thrombogenicity Emulator uses stress-loading waveforms in pertinent platelet flow trajectories that are extracted from highly resolved numerical simulations and emulates these flow conditions in a programmable hemodynamic shearing device (HSD) by which platelet activity is measured. We have previously compared two MHV, ATS and the St. Jude Medical, and demonstrated that owing to its nonrecessed hinge design, the ATS valve offers improved thrombogenic performance. In this study, we further optimize the ATS valve thrombogenic performance, by modifying various design features of the valve, intended to achieve reduced thrombogenicity: 1) optimizing the leaflet-housing gap clearance; 2) increasing the effective maximum opening angle of the valve; and 3) introducing a streamlined channel between the leaflet stops of the valve that increases the effective flow area. We have demonstrated that the DTE optimization methodology can be used as test bed for developing devices with significantly improved thombogenic performance.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcranial Doppler application for risk assessment of stroke in patients with mechanical mitral valve

Introduction: Observing microembolic signals in brain vessels by transcranial Doppler technology is a very common finding in patients with mechanical heart valve. These signals are almost always clinically asymptomatic. The aim of this study was assessment of transcranial Doppler in detecting probability of stroke in patients with mechanical heart valve. Methods: This descriptive study was ca...

متن کامل

Device Thrombogenicity Emulator (DTE)--design optimization methodology for cardiovascular devices: a study in two bileaflet MHV designs.

Patients who receive prosthetic heart valve (PHV) implants require mandatory anticoagulation medication after implantation due to the thrombogenic potential of the valve. Optimization of PHV designs may facilitate reduction of flow-induced thrombogenicity and reduce or eliminate the need for post-implant anticoagulants. We present a methodology entitled Device Thrombogenicty Emulator (DTE) for ...

متن کامل

Numerical Simulation of the Effect of Valve Opening and Particle Concentration on the Erosion Damage in Ball Valves of Pressure Reducing Station

Ball valve is one of valves that have many applications in industry especially in gas delivery systems. This kind of valve is categorized in the on- off flow control valve. This study aims to investigate unusual application of ball valve to control fluid flow in the oil and gas industry and its destructive effect including erosion of ball and body of valve. Simulation of industrial ball valve i...

متن کامل

AN INNOVATIVE SURGIC AL TECHNIQUE FOR CONTINUOUS SUTURING OF PROSTHESIS IN MITR AL VALVE REPL A CEMENT

Mitral valve replacement (MVR) is usually performed in two methods of running and interrupted suturing. In running method, the suturing of the valve is usually with some traction on the annulus and also there is a risk of aortic valve injury. This study was conducted to evaluate a new technique for suturing to avoid these complications and decrease the time of cardiac arrest. One hundred an...

متن کامل

Double Valve Replacement (Mitral and Aortic) for Rheumatic Heart Disease: A 20-year experience with 300 patients.

Introduction: Rheumatic heart disease still remains one of the leading causes of congestive heart failure and death owing to valvular pathologies, in developing countries. Valve replacement still remains the treatment of choice in such patients.The aim of this study wasto analyze the postoperative outcome of  double valve replacement (Mitral and Aortic ) in patients of rheumatic heart disease. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • ASAIO journal

دوره 56 5  شماره 

صفحات  -

تاریخ انتشار 2010