A modified Lewis ECG lead system for ambulatory monitoring of atrial arrhythmias.
نویسندگان
چکیده
BACKGROUND When using a reduced ECG lead system with three leads or less, the analysis of atrial activity during arrhythmias can become problematic due to low signal amplitude and noise. Long ago, Sir Thomas Lewis proposed a lead system for atrial activity enhancement in which two electrodes are placed directly on the chest, however, these leads are sensitive to arm movement artifacts. In this study, a modified Lewis lead system is proposed that is better suited for ambulatory applications since the electrodes are placed in areas with less muscle. MATERIALS AND METHODS The proposed modification is compared to the original Lewis leads as well as to the ES lead of the EASI system. Forty-one healthy volunteers and 10 patients with atrial fibrillation participated. RESULTS The modified Lewis lead has nearly 3 times as large atrial amplitude as the original Lewis leads, and is associated with the largest amplitude of atrial activity when compared to the amplitude of electromyographic activity in healthy volunteers. CONCLUSION The results suggest that the proposed modification of the Lewis lead system has potential to improve ambulatory monitoring of atrial arrhythmias.
منابع مشابه
Arrhythmias in Patients With Pulmonary Hypertension; A Narrative Review of the Current Literature
Incidence and prognostic relevance of supraventricular arrhythmias were evaluated in nine studies. These studies investigated patients with different forms of pulmonary hypertension. Supraventricular arrhythmias were more often found in patients with group two pulmonary hypertension. Common findings in these patients were elevated right atrial pressure and diameters and reduced tricuspid annula...
متن کاملIncidence and timing of potentially high-risk arrhythmias detected through long term continuous ambulatory electrocardiographic monitoring
BACKGROUND Ambulatory electrocardiographic (ECG) monitoring is the standard to screen for high-risk arrhythmias. We evaluated the clinical utility of a novel, leadless electrode, single-patient-use ECG monitor that stores up to 14 days of a continuous recording to measure the burden and timing of potentially high-risk arrhythmias. METHODS We examined data from 122,815 long term continuous amb...
متن کاملUsefulness of ambulatory 7-day ECG monitoring for the detection of atrial fibrillation and flutter after acute stroke and transient ischemic attack.
BACKGROUND AND PURPOSE Although atrial fibrillation is the most frequent cause of cardioembolic stroke, this arrhythmia remains underdiagnosed, as it is often asymptomatic or intermittent and, thus, may not be detected on standard 12-lead ECG or even 24-hour ECG recording (Holter). In this study, we hypothesized that 7-day ambulatory ECG monitoring using an event-loop recording (ELR) device wou...
متن کاملComparison of 24 versus 12 hours of ambulatory ECG monitoring.
In order to assess the additional information obtained from 24 hours compared to 12 hours of ambulatory ECG (electrocardiogram) recording, we analyzed 72 ambulatory ECG monitoring tapes in which arrhythmias were present. In all cases the second 12 hours included the entire period of sleep. Only 38 of 233 (16 percent) episodes of arrhythmias, frequent premature ventricular contractions (PVC's), ...
متن کاملArrhythmias in Patients with Mitral Valve Prolapse
Resting ECGs, exercise treadmill tests and 24-hour ambulatory ECGs were recorded and analyzed in 24 unselected patients with mitral valve prolapse. Arrhythmias were frequent. There were three distinct groups of patients, defined on the basis of total number of premature ventricular contractions (PVCs) during the 24 hours: there were no PVCs in 25%, infrequent PVCs in 25%, and frequent PVCs in 5...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of electrocardiology
دوره 48 2 شماره
صفحات -
تاریخ انتشار 2015