Polyimide polymer glass-free capillary columns for gas chromatography.

نویسندگان

  • Jackie G Webster
  • Susan S Marine
  • Neil D Danielson
چکیده

Polymeric polyimide capillary tubing, both uncoated and coated with stationary phases of two polarities, is explored for use as capillary columns for gas chromatography (GC). These glass-free polyimide columns are flexible and their small winding diameter of less than a cm around a solid support makes them compatible for potential use in portable GC instruments. Polyimide columns with dimensions of 0.32 mm i.d. × 3 m are cleaned, annealed at 300°C, and coated using the static method with phenylmethylsilicone (PMS). Separations of volatile organics are investigated isothermally on duplicate sets of polyimide columns by GC with a flame ionization detector using split injection. Unlike the uncoated ones, the coated polyimide columns successfully separate Grob test mix classes of alkanes, amines, and fatty acid methyl esters. The relative standard deviations for retention time and peak area are 0.5 and 2.5 , respectively. With the 3 m PMS-coated column connected to a retention gap to permit operation at its optimum flow rate of 30 cm/s, a plate count of 3200 or plate height of 1 mm is possible. Lack of retention and tailing peaks are evident for the polyimide polymer capillary columns as compared to that of a 3 m commercial cross-linked PMS fused silica capillary. However, headspace analyses of an aromatic hydrocarbon mix and a Clearcoat automotive paint sample are viable applications on the PMS polyimide polymer column.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-temperature separations on a polymer-coated fibrous stationary phase in microcolumn liquid chromatography.

Novel polymer-coated fiber-packed microcolumns in liquid chromatography (LC) have been developed. Typical polymeric materials, such as polydimethylsiloxane and polyethyleneglycol, which are conventional stationary phases of capillary columns in gas chromatography (GC), have been employed as coating materials onto the surface of fine filaments. Packed longitudinally with a bundle of polymer-coat...

متن کامل

High-resolution gas-chromatographic analysis of the volatile constituents of body fluids, with use of glass capillary columns.

Trace volatile constituents of human urine, serum, and cerebrospinal fluid were concentrated on a porous polymer precolumn, and resolved with high-efficiency glass capillary columns. Thin-film glass columns facilitate effective resolution of underivatized compounds within the volatility range up to docosane in relatively short analysis times. Glass capillary columns coated with stationary phase...

متن کامل

Analysis of bile acids in serum and bile by capillary gas-liquid chromatography.

Various liquid phases for glass capillary columns have been evaluated for gas-liquid chromatographic analysis of methyl ester trimethylsilylether derivatives of bile acids from serum and bile. Bile acid analysis is rapid and exhibits high separation efficiency with a 20 X 0.3 mm glass capillary column whose internal surface is covered with a crystal layer of barium carbonate and coated with pol...

متن کامل

Preparation and characterization of alkyl methacrylate-based monolithic columns for capillary gas chromatography applications.

Gas chromatography (GC) is considered the least common application of both polymer and silica-based monolithic columns. This study describes the fabrication of alkyl methacrylate monolithic materials for use as stationary phases in capillary gas chromatography. Following the deactivation of the capillary surface with 3-(trimethoxysilyl)propyl methacrylate (TMSM), the monoliths were formed by th...

متن کامل

Preparation and Evaluation of Bonded Linear Polymethacrylate Stationary Phases for Open Tubular Capillary Electrokinetic Chromatography

A new procedure for the preparation of thick polymethacrylate films bonded in 25 μm i.d. fused-silica capillaries is developed. The etched silica surface is first modified with an unsaturated organosilane, which is later incorporated into the polymer film. The capillary is then filled with a monomer solution, and polymerization is initiated by incubation at elevated temperature. This thermoinit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatographic science

دوره 49 6  شماره 

صفحات  -

تاریخ انتشار 2011