Arthroscopic Removal of a Displaced Cannulated Screw after Glenoid Rim Fracture - A Case Report
نویسندگان
چکیده
INTRODUCTION Internal fixation has been shown to successfully prevent recurrent dislocations after fractures of the glenoid rim. With regards to fixation either suture anchors or screws can be used, depending on the fragment size. Complications regarding suture anchors and their management have been described previously but not the arthroscopic management of screw impingement. CASE REPORT We present a case of a 70 year old women who suffered from limited range of motion after fixation of a Ideberg III fracture using cannulated screws. X-rays showed one of the screws to be proud. The proud screw could be successfully removed arthroscopically resulting in an improved range of motion, function and decreased pain. CONCLUSION Our report describes a possible technique for performing a procedure arthroscopically that used to be done as an open procedure before and highlights it's limitations.
منابع مشابه
Arthroscopic Reduction with Endobutton Fixation for Glenoid Fracture
Glenoid rim fractures, accompanied by acute glenohumeral dislocation or subluxation usually results in persistent instability. Traditionally open reduction and internal fixation has been recommended in displaced intra-articular glenoid fractures. However, open reduction is difficult, and it may not be possible to address the associated intra-articular soft-tissue injuries. A few reports of arth...
متن کاملAnterior Glenoid Rim Fracture Following Use of Resorbable Devices for Glenohumeral Stabilization
BACKGROUND Resorbable anchors are widely used in arthroscopic stabilization of the shoulder as a means of soft tissue fixation to bone. Their function is to ensure repair stability until they are replaced by host tissue. Complications include inflammatory soft tissue reactions, cyst formation, screw fragmentation in the joint, osteolytic reactions, and enhanced glenoid rim susceptibility to fra...
متن کاملArthroscopic Bony Bankart Repair Using Double-Threaded Headless Screw: A Case Report
We present a case of arthroscopic fixation for bony Bankart lesion using a double-threaded cannulated screw. A 39-year-old man sustained a left shoulder injury from a motorcycle accident. Radiographs showed bony Bankart lesion and CT revealed 40% defect of glenoid articular surface. Arthroscopic fixation was performed using double-threaded cannulated screw after the bony fragment was reduced by...
متن کاملArthroscopic Reduction and Transportal Screw Fixation of Acetabular Posterior Wall Fracture: Technical Note
Acetabular fractures can be treated with variable method. In this study, acetabular posterior wall fracture was treated with arthroscopic reduction and fixation using cannulated screw. The patient recovered immediately and had a satisfactory outcome. In some case of acetabular fracture could be good indication with additional advantages of joint debridement and loose body removal. So, we report...
متن کاملArthroscopic Posterior Glenoid Fracture Fixation Using Knotless Suture Anchors
Shoulder instability after a posterior glenoid rim fracture is rare and potentially difficult pathology to treat. Operative techniques often involve a large dissection to view the fragments resulting in local soft tissue injury. Internal fixation is often achieved with interfragmentary screws; however, this may not be possible with small or multifragmentary fracture patterns. We describe an art...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 3 شماره
صفحات -
تاریخ انتشار 2013