Comparing the relative peripheral refraction effect of single vision and multifocal contact lenses measured using an autorefractor and an aberrometer: A pilot study.
نویسندگان
چکیده
PURPOSE To compare the contributions of single vision (SVCL) and multifocal contact lenses (MFCL) to the relative peripheral refraction (RPR) profiles obtained via an autorefractor and an aberrometer in a pilot study. METHODS Two instruments, Shin-Nippon NVision K5001 (SN) and COAS-HD, were modified to permit open field PR measurements. Two myopic adults (CF, RB) were refracted (cycloplegia) under eight conditions: baseline (no CL); three SVCLs: Focus Dailies(®) (Alcon, USA), PureVision(®) (Bausch & Lomb, USA) and AirOptix(®) (Alcon, USA); and four MFCLs: AirOptix(®) (Alcon, USA), Proclear(®) Distant and Near (Cooper Vision, USA), and PureVision(®) (Bausch & Lomb, USA). CLs had a distance prescription of -2.00D and for MFCLs, a +2.50D Add was selected. Five independent measurements were performed at field angles from -40° to +40° in 10° increments with both instruments. The COAS-HD measures were analyzed at 3mm pupil diameter. Results are reported as a change in the relative PR profile, as refractive power vector components: M, J180, and J45. RESULTS Overall, at baseline, M, J180 and J45 measures obtained with SN and COAS-HD were considerably different only for field angles ≥±30°, which agreed well with previous studies. With respect to M, this observation held true for most SVCLs with a few exceptions. The J180 measures obtained with COAS-HD were considerably greater in magnitude than those acquired with SN. For SVCLs, the greatest difference was found at -40° for AirOptix SV (ΔCF=3.20D, ΔRB=1.56D) and for MFCLs it was for Proclear Distance at -40° (ΔCF=2.58D, ΔRB=1.39D). The J45 measures obtained with SN were noticeably different to the respective measures with COAS-HD, both in magnitude and sign. The greatest difference was found with AirOptix Multifocal in subject RB at -40°, where the COAS-HD measurement was 1.50D more positive. In some cases, the difference in the RPR profiles observed between subjects appeared to be associated with CL decentration. CONCLUSION For most test conditions, distinct differences were observed between the RPR measures obtained with the two modified instruments. The differences varied with CL design and centration. Although the pilot study supports the interchangeable use of the two instruments for on- and off-axis refraction in unaided eyes or eyes corrected with low/no spherical aberration; we advocate the use of the COAS-HD over the SN for special purposes like refracting through multifocal CLs.
منابع مشابه
Analysis of the power profile of a new soft contact lens for myopia progression
1. Wagner S, Conrad F, Bakaraju RC, Fedtke C, Ehrmann K, Holden BA. Power profiles of single vision and multifocal soft contact lenses. Cont Lens Anterior Eye. 2014;38:2--14. 2. Plainis S, Atchison DA, Charman WN. Power profiles of multifocal contact lenses and their interpretation. Optom Vis Sci. 2013;90:1066--1077. 3. Joannes L, Hough T, Hutsebaut X, et al. The reproducibility of a new power ...
متن کاملPeripheral myopization and visual performance with experimental rigid gas permeable and soft contact lens design.
PURPOSE To evaluate the performance of two experimental contact lenses (CL) designed to induce relative peripheral myopic defocus in myopic eyes. METHODS Ten right eyes of 10 subjects were fitted with three different CL: a soft experimental lens (ExpSCL), a rigid gas permeable experimental lens (ExpRGP) and a standard RGP lens made of the same material (StdRGP). Central and peripheral refract...
متن کاملEvaluating the peripheral optical effect of multifocal contact lenses.
PURPOSE Multifocal soft contact lenses have been used to decrease the progression of myopia, presumably by inducing relative peripheral myopia at the same time as the central image is focused on the fovea. The aim of this study was to investigate how the peripheral optical effect of commercially available multifocal soft contact lenses can be evaluated from objective wavefront measurements. M...
متن کاملThe impact of wearing single vision soft contact lenses on the peripheral refractive error
The purpose of this study was to determine the changes in the relative Aim: peripheral refractive error produced by soft single vision contact lenses in myopic schoolchildren. 27 myopic schoolchildren aged between 13 to 15 years were Methods: included in this study. The measurements of central and peripheral refraction were made only on the right eye using a Grand-Seiko WR-5100K open-field auto...
متن کاملPeripheral refraction with different designs of progressive soft contact lenses in myopes
Aim: The purpose of this study was to compare the changes in relative peripheral refractive error produced by two different designs of progressive soft contact lenses in myopic schoolchildren. Methods: Twenty-seven myopic schoolchildren age between 13 to 15 years were included in this study. The measurements of central and peripheral refraction were made using a Grand-Seiko WR-5100K open-field ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of optometry
دوره 8 3 شماره
صفحات -