A clinical experience with a hierarchically controlled myoelectric hand prosthesis with vibro-tactile feedback.
نویسندگان
چکیده
UNLABELLED Improved performance of externally powered myoelectric hands is possible when the direct control of the digit flexion and grip force are given over to an electronic controller which frees the operator to concentrate on other demands. DESIGN A commercial myoelectric hand was modified to take the new touch and slip sensors and novel control method. SUBJECT An adult male with a traumatic mid-forearm amputation. OUTCOME MEASURE The range and ease of use of the prosthetics system. RESULT The hand was easily and usefully operated in the home and work environment. CONCLUSION Hierarchical control of a hand is possible using sensory feedback to a sophisticated electronic controller. Such a control method reduces the demands on the user's concentration and enhances the hand's range.
منابع مشابه
Design and technical construction of a tactile display for sensory feedback in a hand prosthesis system
BACKGROUND The users of today's commercial prosthetic hands are not given any conscious sensory feedback. To overcome this deficiency in prosthetic hands we have recently proposed a sensory feedback system utilising a "tactile display" on the remaining amputation residual limb acting as man-machine interface. Our system uses the recorded pressure in a hand prosthesis and feeds back this pressur...
متن کاملIntelligent multifunction myoelectric control of hand prostheses.
Intuitive myoelectric prosthesis control is difficult to achieve due to the absence of proprioceptive feedback, which forces the user to monitor grip pressure by visual information. Existing myoelectric hand prostheses form a single degree of freedom pincer motion that inhibits the stable prehension of a range of objects. Multi-axis hands may address this lack of functionality, but as with mult...
متن کاملInvestigation of methods for constructing gloves with tactile and force feedback for virtual reality and telecontrol of anthropomorphic manipulators
Aims. Devices that allow using the functionality of natural hand movements are of the greatest interest. The purpose of this study is to select areas of research at the intersection of several fields of science – biomechanics and cybernetics to develop scientific and technical approaches to track the movements of the operator's fingers and form feedback tactile and force communication received ...
متن کاملLong-term results of early myoelectric prosthesis fittings: A prospective case-control study.
BACKGROUND Different recommendations exist regarding what age is best for first-time fitting of myoelectric hand prostheses in children. OBJECTIVES To compare prosthetic skill, prosthetic use and risk for rejection over time between children fitted with myoelectric hand prostheses before or after 2½ years of age. STUDY DESIGN Prospective case-control design. METHODS The cases were nine ch...
متن کاملIntra- and inter-rater reliability of the assessment of capacity for myoelectric control.
OBJECTIVE To examine the reliability of the Assessment of Capacity for Myoelectric Control (ACMC) in children and adults with a myoelectric prosthetic hand. DESIGN Intra-rater and inter-rater reliability estimated from reported assessments by 3 different raters. PATIENTS A sample of convenience of 26 subjects (11 males, 15 females) with upper limb reduction deficiency or amputation and myoe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Prosthetics and orthotics international
دوره 17 1 شماره
صفحات -
تاریخ انتشار 1993