GC/CI-MS/MS method for the identification and quantification of volatile N-nitrosamines in meat products.

نویسندگان

  • Anna Sannino
  • Luciana Bolzoni
چکیده

A sensitive and selective method was developed and validated for the determination of nine N-nitrosamines in meat products. The N-nitrosamines were extracted with NaOH/methanol, partitioned into dichloromethane on a ChemElut column and cleaned-up by solid-phase extraction. All samples were spiked with (2)H isotope-labelled N-nitrosamine internal standard prior to extraction. After purification on a Florisil mini-column, the extracts were analysed by gas chromatography-chemical ionisation tandem mass spectrometry (GC-CI/MS/MS) using ammonia as reagent gas. The presence of N-nitrosamines in samples was quantified by isotope dilution mass spectrometry. The method was validated for linearity and range, accuracy, precision and sensitivity. Recoveries were calculated at three levels of concentration (0.5, 1 and 10 μg/kg) spiked in raw pork meat. The values were found between 95% and 110% with relative standard deviation (RSD) values between 5% and 11%. The excellent selectivity and sensitivity allows quantification and identification of low levels of N-nitrosamines in meat products (limits of quantitation (LOQs) 0.3-0.4 μg/kg). Finally, the method was successfully used to analyse a sample of canned meat and nine different cured meat products produced in Italy. N-Nitroso-dimethylamine was detected in all examined products in the range 0.3-1.1 μg/kg.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

N-nitrosamines in processed meat products

A sensitive, selective and generic method has been developed for the simultaneous determination of the contents ( g kg−1 range) of both volatile nitrosamines (VNA) and non-volatile nitrosamines (NVNA) in processed meat products. The extraction procedure only requires basic laboratory equipment and a small volume of organic solvent. Separation and quantification were performed by the developed L...

متن کامل

Determination of volatile N-nitrosamines in meat products by microwave-assisted extraction coupled with dispersive micro solid-phase extraction and gas chromatography – Chemical ionisation mass spectrometry

A sensitive procedure, microwave-assisted extraction (MAE) coupled dispersive micro solid-phase extraction (D-l-SPE), was developed to extract N-nitrosodimethylamine (NDMA) and other six volatile N-nitrosamines (NAms) from meat products. Parameters affecting the efficiency of MAE and D-l-SPE were systematically investigated. For MAE, 5-g of a homogenised meat sample was extracted with 30 mL of ...

متن کامل

Quantitation of urinary volatile nitrosamines from exposure to tobacco smoke.

A sensitive and selective method was developed and validated to detect six volatile nitrosamines (N-nitrosodimethylamine, N-nitrosomethylethylamine, N-nitrosodiethylamine, N-nitrosopiperidine, N-nitrosopyrrolidine and N-nitrosomorpholine) in human urine. This method uses a liquid-liquid extraction cartridge followed by analysis with gas chromatography-tandem mass spectrometry (GC-MS-MS) and qua...

متن کامل

Identification of Volatile Organic Compounds from Trichoderma virens (6011) by GC-MS and Separation of a Bioactive Compound via Nanotechnology

Fungal volatile organic compounds (VOCs) have the potential of being used as biocontrol agents for biotechnological applications in agriculture, industry and medicine. In this research, different VOCs from secondary metabolites of biocontrol fungus Trichoderma virens (6011) KP671477 were separated using n-hexane, n-butanol and methanol solvents and identified by gas chromatography–mass spectrom...

متن کامل

Impact of Pharmaceutical Impurities in Ecstasy Tablets: Gas Chromatography-Mass Spectrometry Study

In this study, a simple and reliable method by gas chromatograph–mass spectrometry (GC–MS) was developed for the fast and regular identification of 3, 4-MDMA impurities in ecstasy tablets. In so doing, 8 samples of impurities were extracted by diethyl ether under alkaline condition and then analyzed by GC–MS. The results revealed high MDMA levels ranging from 37.6% to 57.7%. The GC-MS method sh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Food chemistry

دوره 141 4  شماره 

صفحات  -

تاریخ انتشار 2013