Transcatheter device closure of patent ductus arteriosus.

نویسندگان

  • Mehboob Sultan
  • Maad Ullah
  • Nadeem Sadiq
  • Khurram Akhtar
  • Hajira Akbar
چکیده

OBJECTIVE To determine the efficacy, safety and immediate complications encountered during percutaneous device closure of patent ductus arteriosus (PDA). STUDY DESIGN Case series. PLACE AND DURATION OF STUDY Department of Paediatric Cardiology, AFIC/NIHD, Rawalpindi, from January 2005 to December 2010. METHODOLOGY Consecutive 500 patients who underwent attempted transcatheter PDA device closure were included in the study. Device type position, success of closure and complications were described as frequency percentage. RESULTS In 491 cases (98.2%), PDA was successfully occluded including 4 cases (0.8%) where devices were dislodged but retrieved and redeployed in Cath laboratory. PDA occluder devices used in 448 cases (91%) while coils (single or multiple) were used in 42 cases (8.5%) and in one case (0.2%) ASD occluder device was used to occlude the PDA. There were 09 (1.8%) unsuccessful cases, 06 (1.2%) were abandoned as ducts were considered unsuitable for device closure, 02 (0.4%) devices dislodged and needed surgical retrieval and one case (0.2%) was abandoned due to faulty equipment. The narrowest PDA diameter ranged from 0.5-14 mm with mean of 4.5±2.4 mm. There was a single (0.2%) mortality. CONCLUSION Transcatheter occlusion of PDA by coil or occluder device is an effective therapeutic option with high success rate. Complication rate is low in the hands of skilled operators yet paediatric cardiac surgical back-up cover is mandatory.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcatheter closure of patent ductus arteriosus.

More than three decades have passed since the introduction of transcatheter devices for closure of patent ductus arteriosus, and many occluders have been made available since then. The ideal requirements of any procedure are a user-friendly technique, optimum success rate, no residual anomaly, minimal morbidity/mortality, and comparability or superiority to the existing conventional modality of...

متن کامل

Transcatheter closure of the patent ductus arteriosus.

Patent ductus arteriosus (PDA) is one of the most common congenital heart defects. Although surgery is still required in symptomatic neonates, the majority of older infants and children can undergo safe and effective transcatheter device closure on an out-patient basis. First described in 1967, over the past four decades, numerous devices have been specifically developed for this purpose. This ...

متن کامل

Transcatheter closure of post-operative residual ventricular septal defect using a patent ductus arteriosus closure device in an adult: a case report.

Transcatheter closure of perimembranous and muscular ventricular septal defect (VSD) has been performed widely and it has more advantages compare to surgery. However, transcatheter closure of residual VSD post operation of complex congenital heart disease is still challenging because of the complexity of anatomy and concern about device stability, so the operator should meticulously choose the ...

متن کامل

Clinical outcome of transcatheter closure of patent ductus arteriosus in small children weighing 10 kg or less

PURPOSE Transcatheter closure has become an effective therapy in most patients with patent ductus arteriosus (PDA). However, there are difficulties in transcatheter closure of PDA in small children. We reviewed clinical outcomes of transcatheter closure of PDA in children weighing less than 10 kg in a single center. METHODS Between January 2003 and December 2009, 314 patients with PDA underwe...

متن کامل

Severe hemolysis complicating transcatheter occlusion of a patent ductus arteriosus: the importance of elimination of residual flow.

Transcatheter closure of a patent ductus arteriosus (PDA) is an established technique that may rarely be complicated by severe intravascular hemolysis due to residual shunt. Although conservative management has been reported, the usual approach is to invasively eliminate the residual shunt. We report a case where misjudgment of PDA size and subsequent attempted closure with only one coil led to...

متن کامل

[Transcatheter closure of patent ductus arteriosus using the Amplatzer duct occluder: initial results and mid-term follow-up].

INTRODUCTION AND OBJECTIVES Transcatheter closure of patent ductus arteriosus is a well-established procedure. The aim of this study was to assess the initial and mid-term results of the treatment of PDA with the Amplatzer duct occluder. PATIENTS AND METHODS From October 1999 to December 2001, 30 children underwent transcatheter closure of persistent ductus arteriosus at a mean SD age of 5 4....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the College of Physicians and Surgeons--Pakistan : JCPSP

دوره 24 10  شماره 

صفحات  -

تاریخ انتشار 2014