Introduction of new industry standards for cardiac implantable electronic devices: balancing benefits and unexpected risks

نویسندگان

  • Christian Sticherling
  • Haran Burri
چکیده

The DF-4 connector is a novel industry standard for the connection of a defibrillator lead to the generator. It aims at reducing the bulk created by two or three pins at the proximal end of the defibrillator lead and its corresponding ports at the header of the device. Having only one connection port between the lead and the device reduces the material in the pocket, the risk of lead-to-port mismatch, may lower the risk of lead abrasion, and probably makes the implantation procedure a little easier since only one set screw is required. However, all these conceived benefits are related to convenience rather than to a medical need. After the recent experiences with the possible negative clinical impact of 'minor' changes like simply downsizing a defibrillator lead, a word of caution is warranted. The lead is the weakest part of the defibrillator system, complex in design and undergoing constant stress through movement. It is very hard to predict which issues may evolve over time with the changes in lead design. Does the perceived benefit really outweigh an unpredictable risk in a sensitive medical product like a defibrillator? This article tries to address the possible issues of the new spring contacts instead of set screws, the proximity of the low- and high-voltage connections as well as the inability of adding a pace/sense or an additional shock lead without a special adaptor, and advocates a measured speed in the introduction of this technology.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interference in implanted cardiac devices, Part I.

Sensing intrinsic cardiac electrical activity is essential for the function of pacemakers and implantable cardioverter defibrillators (ICDs). Examples of undesired triggering or inhibition of pacemaker output by extraneous signals were identified early after the introduction of noncompetitive, “demand” pacemakers. Hermetic shielding in metal cases, filtering, and interference rejection circuits...

متن کامل

The Investigation and Analysis of the Strengths, Weaknesses, Opportunities, and Threats of Wearable Electronic Technologies: A Systematic Review

Introduction: Wearable electronic devices, which are based on Internet of Things (IoT) and big data computing, are able to continuously collect and process the physiological and environmental data and exchange them with other tools, users, and internet networks. Therefore, despite their potential benefits in health monitoring, they can pose serious risks, especially in breach of privacy. Hence...

متن کامل

The Investigation and Analysis of the Strengths, Weaknesses, Opportunities, and Threats of Wearable Electronic Technologies: A Systematic Review

Introduction: Wearable electronic devices, which are based on Internet of Things (IoT) and big data computing, are able to continuously collect and process the physiological and environmental data and exchange them with other tools, users, and internet networks. Therefore, despite their potential benefits in health monitoring, they can pose serious risks, especially in breach of privacy. Hence...

متن کامل

Radiation Therapy to Patients with Cardiac Implanted Electronic Devices

There is an increase of the number of patients with cardiac implantable electronic devices (CIEDs, like pacemakers and cardioverter defibrillators) that require radiotherapy for cancer treatment. Managing such patients has been a great practical and procedural challenge in radiation oncology practice. This editorial will focus on outlining the most important risks of using new techniques of rad...

متن کامل

Advances in Arrhythmia and Electrophysiology Microbiology and Pathogenesis of Cardiovascular Implantable Electronic Device Infections

Advancements in our understanding of cardiac conduction abnormalities and pathophysiology of congestive heart failure coupled with innovations in device manufacturing and programming have helped to create a demand for a plethora of newer cardiovascular devices over the past 3 decades. Appropriate use of cardiovascular implantable electronic devices (CIEDs) in carefully selected patients is asso...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2012