Electron Capture Detector with Non-Radioactive Electron Source

نویسندگان

  • Ansgar T. Kirk
  • Jens Oermann
  • Stefan Zimmermann
چکیده

Gas chromatographs equipped with electron capture detectors (ECD) are widely used for the analysis of electron affine substances. Achieving limits of detection in the low pptv-range, electron capture detectors are the most sensitive detectors available for such compounds. Based on their operating principle, they require free electrons at atmospheric pressure, which are usually generated by using a β--decay. However, the use of radioactive materials leads to regulatory restrictions regarding purchase, operation and disposal. Here, we present a new electron capture detector using a non-radioactive electron source, which is not subject to these limitations and offers further advantages such as adjustable and higher electron densities and energies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Isosorbide Dinitrate in Serum by Gas Chromatography with New Generation of Electron Capture Detector and its Application in Pharmacokinetic Study

Isosorbide dinitrate (ISDN) is an effective drug in treatment of angina pectoris. In this study a new generation of electron capture detector (non-radioactive) with a short, non-polar and wide-bore column was used for analysis of ISDN in human serum. ISDN was extracted from serum by a mixture of ether and ethyl acetate and concentrated at room temperature. The method was linear between 5-50...

متن کامل

Determination of Isosorbide Dinitrate in Serum by Gas Chromatography with New Generation of Electron Capture Detector and its Application in Pharmacokinetic Study

Isosorbide dinitrate (ISDN) is an effective drug in treatment of angina pectoris. In this study a new generation of electron capture detector (non-radioactive) with a short, non-polar and wide-bore column was used for analysis of ISDN in human serum. ISDN was extracted from serum by a mixture of ether and ethyl acetate and concentrated at room temperature. The method was linear between 5-50...

متن کامل

Fast gas chromatography of explosive compounds using a pulsed-discharge electron capture detector.

The detection of a mixture of nine explosive compounds, including nitrate esters, nitroaromatics, and a nitramine in less than 140 sec is described. The new method employs a commercially available pulsed-discharge electron capture detector (PDECD) coupled with a microbore capillary gas chromatography (GC) column in a standard GC oven to achieve on-column detection limits between 5 and 72 fg for...

متن کامل

Design and Simulation of Photoneutron Source by MCNPX Monte Carlo Code for Boron Neutron Capture Therapy

Introduction Electron linear accelerator (LINAC) can be used for neutron production in Boron Neutron Capture Therapy (BNCT). BNCT is an external radiotherapeutic method for the treatment of some cancers. In this study, Varian 2300 C/D LINAC was simulated as an electron accelerator-based photoneutron source to provide a suitable neutron flux for BNCT. Materials and Methods Photoneutron sources w...

متن کامل

Combining dark matter detectors and electron-capture sources to hunt for new physics in the neutrino sector

In this letter we point out the possibility to study new physics in the neutrino sector using dark matter detectors based on liquid xenon. These are characterized by very good spatial resolution and extremely low thresholds for electron recoil energies. When combined with a radioactive νe source, both features in combination allow for a very competitive sensitivity to neutrino magnetic moments ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017