Manual versus automatic sampling variations of a preliminary alcohol screening device.

نویسندگان

  • Sandra C Bishop
  • Glenn Johnson
  • Lisa Smith
  • Dary D Fiorentino
  • Tatiana Garcia
  • Rafael Garcia
  • Christopher Breyer
  • Warren D Loomis
چکیده

Utilization of a manual sampling function as an alternative to the automatic sampling function in the Alco-Sensor IV Black Dot Model has been recognized by the manufacturer to potentially underestimate an individual's true breath alcohol content (BrAC). A controlled human subject study was conducted to analyze the possible breath-sampling differences between the standard automatic technique and three manual techniques. Subjects were dosed with vodka and orange juice and then tested during the descending limb of their BrAC curve. Differences between the automatic and the manual techniques were found to be statistically significant with the three manual techniques underestimating the BrAC. The average maximum difference between the automatic BrAC level, as compared to the lowest manual level in each data set, was 27.9% (median 27.7%) with underestimations from 20.8% to 40.0%. In no instance did any of the manual techniques produce higher BrACs than the automatic technique.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing the Accuracy of Waist-Hip Ratio Calculation by the BIA device versus the Manual Method

Nowadays, the Waist-Hip Ratio is considered one of the most important indices in predicting the risk of cardiovascular diseases. The usual method for calculating this index is by measuring the waist and hip circumferences with a measuring tape. However, bioelectrical impedance analysis (BIA) devices are also capable of calculating this ratio. Hence, the goal of this study was to calculate this ...

متن کامل

Translation and cross-cultural adaptation of a new Persian version of Language Assessment, Remediation, and Screening Procedure: A Preliminary Norm-Referenced Morphosyntactic Sketch for Persian-Speaking Children Aged 2-5 years

Introduction: In 1998, the Persian form of Language Assessment, Remediation, & Screening Procedure (P-LARSP) was introduced. However, this adapted version remained on library shelves and was not used by Iranian speech and language pathologists (SLPs). The present study aimed to explore the barriers to using P-LARSP, resolve the possible issues, and provide a preliminary grammatical sketch from ...

متن کامل

Design and Construction of an Automatic pH Adjustment System by Instant Feedback Method

Evaluations of the acidity or alkalinity of solutions are used in many industries such as food industries, medicine, chemical engineering, petrochemical industries, agriculture, animal husbandry, industrial laboratories, etc. Portable and stationary pH measurements are very common and are an integral part of these studies, due to the importance of pH. In most of these evaluations and studies, a...

متن کامل

Comparison of manual and automatic sampling for monitoring ochratoxin A in barley grain

Automatic and manual sampling for ochratoxin A (OTA) in barley grain was compared under industrial conditions considering sampling uncertainty as well as practical and technical aspects. Ten tonnes of barley inoculated with Penicillium verrucosum were incubated until the OTA concentration reached approximately 15 µg kg(-1) and sampled with manual and automatic sampling. A nested experimental de...

متن کامل

Automatic adaptation of neurostimulation therapy in response to changes in patient position: results of the Posture Responsive Spinal Cord Stimulation (PRS) Research Study.

BACKGROUND Variation in the intensity of neurostimulation with body position is a practical problem for many patients implanted with a spinal cord stimulation system because positional changes may result in overstimulation or understimulation. These posture-related changes in patients' perception of paresthesia can affect therapeutic outcomes of spinal cord stimulation therapy. An accelerometer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of analytical toxicology

دوره 33 8  شماره 

صفحات  -

تاریخ انتشار 2009