Bioengineering of Improved Biomaterials Coatings for Extracorporeal Circulation Requires Extended Observation of Blood-Biomaterial Interaction under Flow

نویسندگان

  • Kris N. J. Stevens
  • Yvette B. J. Aldenhoff
  • Frederik H. van der Veen
  • Jos G. Maessen
  • Leo H. Koole
چکیده

Extended use of cardiopulmonary bypass (CPB) systems is often hampered by thrombus formation and infection. Part of these problems relates to imperfect hemocompatibility of the CPB circuitry. The engineering of biomaterial surfaces with genuine long-term hemocompatibility is essentially virgin territory in biomaterials science. For example, most experiments with the well-known Chandler loop model, for evaluation of blood-biomaterial interactions under flow, have been described for a maximum duration of 2 hours only. This study reports a systematic evaluation of two commercial CPB tubings, each with a hemocompatible coating, and one uncoated control. The experiments comprised (i) testing over 5 hours under flow, with human whole blood from 4 different donors; (ii) measurement of essential blood parameters of hemocompatibility; (iii) analysis of the luminal surfaces by scanning electron microscopy and thrombin generation time measurements. The dataset indicated differences in hemocompatibility of the tubings. Furthermore, it appeared that discrimination between biomaterial coatings can be made only after several hours of blood-biomaterial contact. Platelet counting, myeloperoxidase quantification, and scanning electron microscopy proved to be the most useful methods. These findings are believed to be relevant with respect to the bioengineering of extracorporeal devices that should function in contact with blood for extended time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Macrophage response to staphylococcal biofilms on crosslinked poly(ethylene) glycol polymer coatings and common biomaterials in vitro.

Biomaterial-associated-infections (BAI) are serious clinical complications that threaten the longevity of implanted devices and lead to high morbidity and mortality. Poly(ethylene)glycol (PEG) coatings have been studied as a strategy to reduce the incidence of BAI by reducing protein deposition that promotes pathogen adhesion and growth on device surfaces. Despite their effectiveness to reduce ...

متن کامل

Comparison of the Effect of Hydrophilicity on Biocompatibility and Platelet Adhesion of Two Different Kinds of Biomaterials

      Determination of blood compatibility is an important problem in blood contacting devices. In this study, two classes of materials including polyurethane (based on polyethylene glycol and poly tetrametylene oxide) and polyvinyl alcohol samples, with different hydrophilicity properties were synthesized and their physico-chemical properties were compared. Water uptake ratio, FTIR spectroscop...

متن کامل

Comparison of microscopic methods for evaluating platelet adhesion to biomaterial surfaces.

Microscopic methods usable for sample surface imaging and subsequent qualitative and quantitative evaluation of platelet adhesion to the surface of the biomaterial studied were compared. It was shown, making use of the samples of medical steel (AISI 316L), that such tools as surface imaging with scanning electron microscopy (SEM), glutaraldehyde induced fluorescence technique (GIFT) and metallu...

متن کامل

Binding of a model regulator of complement activation (RCA) to a biomaterial surface: surface-bound factor H inhibits complement activation.

The complement system is an important inflammatory mediator during procedures such as cardiopulmonary bypass and hemodialysis when blood is exposed to large areas of biomaterial surface. This contact between blood and the biomaterials of implants and extracorporeal circuits leads to an inflammatory response mediated by the complement system. The aim of this study was to assess the ability of a ...

متن کامل

Stability and effectiveness against bacterial adhesion of poly(ethylene oxide) coatings in biological fluids.

Poly(ethylene oxide) (PEO) coatings have been shown to reduce the adhesion of different microbial strains and species and thus are promising as coatings to prevent biomaterial-centered infection of medical implants. Clinically, however, PEO coatings are not yet applied, as little is known about their stability and effectiveness in biological fluids. In this study, PEO coatings coupled to a glas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Biomedicine and Biotechnology

دوره 2007  شماره 

صفحات  -

تاریخ انتشار 2007