Hydroxyapatite-coated stems with metaphyseal and diaphyseal press-fit. Eleven-year follow-up results.
نویسندگان
چکیده
We report the 11-year follow-up results of 52 unilateral primary hip arthroplasties performed with hydroxyapatite-coated stems. The femoral prosthesis used was a collarless titanium alloy implant, with proximal circumferential hydroxyapatite coating and increased distal thickness to fit the proximal diaphyseal region of the femur. Clinical evaluation was performed using the Merle d'Aubigné Hip Score. Anteroposterior and lateral radiographs were obtained and compared with previous postoperative films. Radiographic evaluation was carried out following Engh's criteria for uncemented implant fixation and using Livermore's method for measurement of polyethylene wear. At the end of the follow-up period, excellent and good clinical results were recorded in 40 arthroplasties (77%). The incidence of thigh pain at one year was 32.7%, but it decreased to 4.2% after the first post-operative year. The 11-year survival rate was 92.3%. Seven arthroplasties were revised because of aseptic loosening of the cup in one case, aseptic loosening of the stem, in one case, septic loosening of the stem in one case, periprosthetic fracture in two cases and polyethylene wear in three cases. Forty-two (87.5%) of the nonrevised stems met the criteria for radiographic osseointegration. Cortical hypertrophy was observed around the mid-part and tip of the stem in 22 patients of the series. This sign tends to be related to thigh pain (p < 0.1). Calcar osteolysis was present in 8 cases. There was only one case of distal femoral osteolysis. We found a strong and significant relationship between long-term wear rates and the occurrence of osteolysis (p < 0.001). We concluded that thigh pain is in relation to the distal diameter of the stems and significantly decreases after the first postoperative year. There was a low incidence of osteolysis in our series in comparison with other series of noncemented implants with 32-mm femoral heads and with similar follow-up.
منابع مشابه
An in vitro study of the strain distribution in human femora with anatomical and customised femoral stems.
Hydroxyapatite-coated standard anatomical and customised femoral stems are designed to transmit load to the metaphyseal part of the proximal femur in order to avoid stress shielding and to reduce resorption of bone. In a randomised in vitro study, we compared the changes in the pattern of cortical strain after the insertion of hydroxyapatite-coated standard anatomical and customised stems in 12...
متن کاملA single dose zoledronic acid enhances pin fixation in high tibial osteotomy using the hemicallotasis technique. A double-blind placebo controlled randomized study in 46 patients.
INTRODUCTION Bisphosphonates have been shown to reduce osteoclastic activity and enhance pin fixation in both experimental and clinical studies. In this prospective, randomized study of high tibial osteotomy using the hemicallotasis (HCO) technique, we evaluate whether treatment by one single infusion of zoledronic acid can enhance the pin fixation. MATERIALS AND METHODS 46 consecutive patien...
متن کاملRevision TKA with a condylar constrained prosthesis using metaphyseal and surface cementation: a minimum 6-year follow-up analysis
BACKGROUND The increasing number of revision knee arthroplasty result in the more frequently use of a constraint implant but results from previous reports are difficult to interpret. The purpose of this study was to compare the long-term outcomes of superficial cemented versus metaphyseal cemented in revision total knee arthroplasty with a condylar constrained arthroplasty. METHODS The study ...
متن کاملHigh 10-Year Survival Rate with an Anatomic Cementless Stem (SPS)
BACKGROUND Proximal cementless fixation using anatomic stems reportedly increases femoral fit and avoids stress-shielding. However, thigh pain was reported with the early stem designs. Therefore, a new anatomic cementless stem design was based on an average three-dimensional metaphyseal femoral shape. However, it is unclear whether this stem reduces the incidence of thigh pain. QUESTIONS/PURP...
متن کاملThe Short-term Clinical Outcome of Total Hip Arthroplasty Using Short Metaphyseal Loading Femoral Stem
PURPOSE The purpose of this study was to retrospectively evaluate the short-term clinical and radiological outcomes of total hip arthroplasty (THA) with short metaphyseal loading femoral stem. MATERIALS AND METHODS We retrospectively reviewed the records of 56 cases in 47 patients who had undergone THA with short metaphyseal loading femoral stem from April 2010 to December 2011. There were 20...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Acta orthopaedica Belgica
دوره 68 1 شماره
صفحات -