An Assessment of the Suitability of the Body and Adult Head Coils for Transmission During Paediatric Magnetic Resonance Imaging
نویسندگان
چکیده
MRI offers physiological and diagnostic advantages over other modalities (CT, PET) and, if examining a paediatric patient, the lack of ionizing radiation is especially important. However, the process for infants is limited by the radio-frequency (RF) coils currently available which are optimized for adult anatomy. Simulation is used to confirm the safety of the coil and design performance. The aim of this work is to calculate Specific Absorption Rate (SAR) and the homogeneity of the RF transmit field (B1+) when imaging infants using COMSOL Multiphysics®. Use of COMSOL Multiphysics® The electromagnetic characterization of birdcage-type coils used to create the transmitted field can be simulated using the RF Module provided by COMSOL Multiphysics® [1]. This coil geometry can be parameterised and therefore easily adapted to differently sized designs. After tuning, two voltage ports create a quadrature excitation. The tuned coil is loaded by an anatomical model and B1+ is then assessed for homogeneity within a region of interest (ROI). An FEM-compatible baby model was built for this purpose (Figure 1). SAR values are normalized to the research regulatory limit of 4W/kg over the entire body and the patient volume is subsequently examined for local 'hot spots' which exceed the local SAR limit for a 1g cube of tissue. Voxel phantoms have been employed previously in the examination of adult phantoms using the FDTD method [3], but place computational constraints on FEM meshes and solvers. Variables and MATLAB Simulink were used to calculate SAR at regular positions without the use of voxel-based anatomical models. Though SAR and temperature increase are related, physiological factors may influence their location [4]. COMSOL's Bioheat Transfer interface enables tissue heating calculation with consideration of both metabolic rates of tissues and perfusion of blood. Results Initial results confirm that the body coil produces a more homogeneous B1+ (Figure 2). However, maximum normalised SAR is lower for the local coil transmit with a maximum value of 63.35 W/kg compared to 67.37W/kg though in both instances the value did exceed 1g limits in the neck and arm regions. Thermal maps indicate small temperature rises in the highest SAR regions but also cooling from the skin surface (Figures 3-4). Conclusions The lower SAR arising from local transmit seems counter-intuitive as the baby is closer to the conducting elements and SAR is proportional to the electric field, however, small changes between the relative position of the patient have been shown to alter this maximum greatly [3,5]; inside the local (head) coil the baby is not entirely exposed to RF so SAR is reduced. The COMSOL Multiphysics® simulation conforms to previous calculations of SAR maps using the industry standard software [5]. With confidence in this result other aspects of coil optimisation and safety for paediatrics can be addressed, such as Signal to Noise Ratio or the effect of thermo-regulation on patient temperature change.
منابع مشابه
Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)
Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...
متن کاملAssessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences
Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of non-homogeneity in RF receive and transmit. This can be the most effective source of error in quantitative studies in MRI imaging. Part of this non-homogeneity demonstrates the characteristics of RF coil and part of it is due to the interaction of RF field with the material being imaged...
متن کاملDesigning and Fabrication of a New Radiofrequency Planar microcoil for mini-Nuclear Magnetic Resonance
Introduction Radiofrequency planar microcoils are used to increase the resolution of magnetic resonance images of small samples. In this study, we aimed to design and fabricate a spiral planar microcoil constructed on a double-sided printed circuit board (PCB). It has four rings with an internal diameter of 241 microns tuned and matched at 63.8 MHz. Materials and Methods To achieve the maximum ...
متن کاملAssessment of Organ Specific Iron Overload in Transfusion-dependent Thalassemia by Magnetic Resonance Imaging Techniques
The consequence of repeated blood transfusions in thalassemia is iron overload in different organs. Magnetic resonance imaging (MRI) is a reliable, non-invasive and accurate method for iron detection in various tissues, hence the introduction of MRI has revolutionized the management of these patients and improved the life expectancy of them. Cardiac MRI T2* has a profound effect not only on est...
متن کاملبررسی شدت نسبی سیگنال تصاویر Magnetic Resonance در بافت رترودیسکال و عضله پتریگوئید خارجی و رابطه آن با یافتههای Magnetic Resonance Imaging
Background and Aims: Disc displacement is the most common temporomandibular joint disorder and magnetic resonance imaging (MRI) is the gold standard in its diagnosis. This disorder can lead to changes in signal intensity of magnetic resonance (MR). The purpose of this study was evaluation of correlation between relative signal intensity of MR images of retrodiscal tissue, superior and inferior ...
متن کاملDynamic Contrast Magnetic Resonance Imaging (DCE-MRI) and Diffusion Weighted MR Imaging (DWI) for Differentiation between Benign and Malignant Salivary Gland Tumors
Background: Salivary gland tumors form nearly 3% of head and neck tumors. Due to their large histological variety and vicinity to facial nerves, pre-operative diagnosis and differentiation of benign and malignant parotid tumors are a major challenge for radiologists. Objective: The majority of these tumors are benign; however, sometimes they tend to transform into a malignant form. Functional M...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2013