Quantitative assessment of left ventricular perfusion defects using real-time three-dimensional myocardial contrast echocardiography.
نویسندگان
چکیده
Quantitative assessment of perfusion defects with myocardial contrast echocardiography can be a valuable tool in the evaluation of patients with coronary artery disease. However, the use of 2-dimensional echocardiography for this purpose is limited to a restricted number of imaging planes. Real-time 3-dimensional echocardiography (RT3D) is a novel technique that provides instantaneous volumetric images. The aim of this study was to validate the use of RT3D for the quantitative assessment of myocardial perfusion defects in a model of acute coronary occlusion. To this end, 20 sheep underwent acute ligation of the left anterior descending (n = 14) or the posterior branch of the circumflex (n = 6) artery under general anesthesia. The RT3D images were obtained after left atrial injection of the contrast agent EchoGen (perflenapent emulsion; 0.8-1 mL). Evans blue dye was injected into the occluded coronary artery for subsequent anatomic identification of underperfused myocardium. The mass of the entire left ventricle and of the underperfused myocardial region were measured after death. Blinded off-line calculation of left ventricular (LV) mass and perfusion-defect mass from RT3D images were performed using an interactive aided-manual tracing technique. Total LV mass ranged from 68 to 141 g (mean plus minus SD: 92 +/- 24 g). The mass of the perfusion defect ranged from 0 to 43 g (mean +/- SD: 16 +/- 9 g) or 0 to 36% of total LV mass (mean +/- SD: 18% +/- 9%). The RT3D estimation of total LV mass strongly correlated with the anatomic measurement (r = 0.91; y = -2.54 + 1.04x; standard error of the estimate [SEE] = 11.9 g). The RT3D calculation of the mass of underperfused myocardium also strongly correlated with the anatomic measurement, both in absolute terms (r = 0.96; y = 2.01 + 0.87x; SEE = 2.2 g) and when expressed as percentage of total LV mass (r = 0.96; y = 0.11 + 1.02x; SEE = 2.8%). Hence, RT3D with myocardial contrast opacification accurately predicts the amount of underperfused myocardium in an animal model of acute coronary occlusion. This technique may therefore be useful for the quantitative assessment of myocardial perfusion defects in patients with coronary artery disease.
منابع مشابه
Diastolic left ventricular functional indices: Comparison between gated myocardial perfusion SPECT and echocardiography
Introduction: Many patients have only diastolic dysfunction without any abnormality in systolic function. We compared cardiac diastolic parameters obtained by gated myocardial perfusion SPECT (Gated SPECT) with those evaluated by echocardiography. Methods: Forty-nine patients (aged 37-85 years, 19 males and 30 women) underwent Gated SPECT and echocardiogr...
متن کاملResults of performing or not cardiac resynchronization therapy for live assessment of LV function and mechanical systole synchrony using gated myocardial perfusion imaging and real-time three-dimensional echocardiography. Seven months follow-up.
We studied a 50 years old male patient who underwent cardiac resynchronization therapy on and off (CRT-on and CRT-off) for assessment of left ventricular (LV) function and mechanical systole synchrony using gated myocardial perfusion imaging (gMPI) and real-time three-dimensional echocardiography (RT3DE). The patient was reexamined after seven months. The comparison of these two modalities show...
متن کاملDipyridamole stress and rest gated 99mTc-sestamibi myocardial perfusion SPECT: left ventricular function indices and myocardial perfusion findings
Introduction: We investigated the difference in left ventricular ejection fraction (LVEF) and end-systolic volume(ESV) measured by gated myocardial perfusion SPECT (GSPECT) in the post-dipyridamole stress and rest periods, and compared the results with the perfusion patterns found in the conventional non-gated tomograms. Methods: 297 consecutive patients were studie...
متن کاملAbnormal coronary reserve and left ventricular wall motion during cold pressor test in patients with previous left ventricular ballooning syndrome.
AIMS To investigate whether and how cold pressor test (CPT) could affect myocardial perfusion and left ventricular (LV) function in patients with previous LV ballooning syndrome (LVBS). METHODS AND RESULTS Cold pressor test (3 min hand immersion in ice-water) was performed in 17 women with previous LVBS and in 7 age- and risk factor-matched women with chest pain and normal coronary arteries. ...
متن کاملClinical applications of contrast echocardiography.
Advances in the engineering of transpulmonary ultrasound contrast agents have greatly enriched contemporary two-dimensional (2D) echocardiography, a technique that has became the most commonly employed imaging tool in cardiology. The currently approved application of contrast echocardiography is far left ventricular opacification (LVO) and enhanced endocardial border delineation (EBD) in patien...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography
دوره 15 3 شماره
صفحات -
تاریخ انتشار 2002