The combined anteversion technique for acetabular component anteversion.

نویسندگان

  • Christopher Amuwa
  • Lawrence D Dorr
چکیده

The combined anteversion technique for acetabular component placement of total hip arthroplasty is beneficial because of the surgeons' limited ability to control the anteversion of a cementless femoral stem. Our data show that the cementless stem anteversion can be 15 degrees different than anticipated. By determining femoral stem anteversion before positioning cup anteversion, the cup anteversion can be adjusted for the stem anteversion. The combined anteversion technique should provide a mean near 35 degrees with a safe zone of 25 degrees to 50 degrees.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of native anatomy with recommended safe component orientation in total hip arthroplasty for primary osteoarthritis.

BACKGROUND The adverse consequences of impingement, dislocation, and implant wear have stimulated increasing interest in accurate component orientation in total hip arthroplasty and hip resurfacing. The aims of the present study were to define femoral and acetabular orientation in a cohort of patients with primary hip osteoarthritis and to determine whether the orientation of their native hip j...

متن کامل

Acetabular Component Anteversion in Primary and Revision Total Hip Arthroplasty: An Observational Study

PURPOSE In a prospective manner to evaluate the range of acetabular component anteversion actually achieved by the use of a cup positioner in cementless revision and primary THA. METHODS We operated 71 patients with cementless primary THA, and 26 patients with cementless acetabular revision surgery. We aimed to obtain cup anteversion of 10 to 30° with an impactor-positioner. In all cases we u...

متن کامل

Anatomic Anteversion of the Acetabular Component Correlates with Polyethylene Linear Wear in Total Hip Arthroplasty: The Three-Dimensional Numerical Analysis

Background: Although abduction of the acetabular component is considered to predict factors for polyethylene wear attributable to osteolysis, other radiographic factors have yet to be elucidated. The purpose of the present study was to evaluate whether anteversion or change in implantation angle of the acetabular component influences polyethylene linear wear by using standing and supine radiogr...

متن کامل

A method to calculate the acetabular cup anteversion after total hip replacement based on 3D coordinate system

Aim: To explore an accurate method to calculate acetabular cup anteversion after total hip arthroplasty. Method: 1) A 3D coordinate system was established with the center of the hip joint rotation center base as coordinate center. The acetabular exit plane and Pettersson formula acetabular anteversion and Riten Pradhan formula acetabular anteversion and acetabular true anteversion were drawn; 2...

متن کامل

The role of the transverse acetabular ligament in total hip arthroplasty.

We performed a systematic literature review to evaluate the role of the transverse acetabular ligament as a reference aid when determining acetabular component anteversion in total hip arthroplasty. We conducted a literature search in the MEDLINE, EMBASE and Pubmed databases using the key words 'transverse acetabular ligament' and 'arthroplasty'. Four studies published between 2006 and 2011, re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of arthroplasty

دوره 23 7  شماره 

صفحات  -

تاریخ انتشار 2008