A preliminary study on adaptive field-of-view tracking in peripheral digital subtraction angiography.
نویسندگان
چکیده
About two million peripheral angiographies are performed annually in the United States, hence a reduction in exposure would yield significant healthcare benefits. The synchronization of bolus traveling, the table motion, and the fluoroscopic imaging chain can be highly effective for dose reduction in Digital Subtraction Angiography (DSA) by minimizing the field-of-view according to the vascular anatomy of the region traveled by the bolus. The goal of this paper is to demonstrate the feasibility of adjusting the field-of-view while tracking the contrast bolus, thus reducing the dosage of both the bolus and the radiation. The speed of the bolus is respectively estimated in the systole and diastole stages. An EKG-gated Hammerstein model is used to predict the bolus chasing speed. A real-time algorithm is designed to extract the bolus dynamics, and define the field of view transversely and longitudinally. A limb stabilization technique is also presented to suppress any significant image misalignment. Our simulation results show that the proposed techniques are promising for clinical applications.
منابع مشابه
Contrast-enhanced MR angiography and digital subtraction angiography in living renal donors: diagnostic agreement, impact on decision making, and costs
Health technology The authors studied contrast-enhanced magnetic resonance angiography (MRA) and digital subtraction angiography (DSA). MR images were obtained using a 1.5-T MR scanner (Signa CV/I, GE Healthcare) with a torso phased-array coil. Digital subtraction images were obtained using a 38-cm field of view and an image matrix of 1,024 x 1,024 pixels (Integris V3000, Philips Medical System...
متن کاملThree-dimensional dynamic MR digital subtraction angiography using sensitivity encoding for the evaluation of intracranial arteriovenous malformations: a preliminary study.
BACKGROUND AND PURPOSE Our aim was to develop 3D dynamic MR digital subtraction angiography with high temporal resolution without sacrificing spatial resolution by using sensitivity encoding for the evaluation of cerebral arteriovenous malformations. METHODS Nineteen patients with 19 angiographically proven arteriovenous malformations (16 supratentorial and 3 infratentorial) were assessed by ...
متن کاملNon-contrast peripheral angiography at 3T using QISS: improving venous suppression
Background Quiescent Interval Single Shot (QISS) has emerged as a robust technique for non-enhanced angiography of peripheral arteries (1). It has been clinically validated with contrast enhanced magnetic resonance angiography (CE-MRA) and digital subtraction angiography (DSA) (2,3). Both of these validation studies were performed at 1.5T field strength. Although the initial experience with QIS...
متن کامل3T versus 1.5T MR angiography in peripheral arterial occlusive disease: an equivalence trial in comparison with digital subtraction angiography
Background Contrast-enhanced MR angiography (CE-MRA) has evolved into a reliable imaging technique for peripheral arterial occlusive disease (PAOD). Recent advances in MRI technology offer large homogeneous magnetic fields with comparable Field-of-Views at 3T and 1.5T, allowing visualization of the complete runoff vascular tree by single-injection 3-station (pelvic/thigh/calf) moving-table CE-M...
متن کاملMotion compensated digital subtraction angiography
Digital subtraction angiography, whether based on traditional X-ray or MR, su ers from patient motion artifacts. Until now, the usual remedy is to pixel shift by hand, or in some cases performing a global pixel shift semi-automatically. This is time consuming, and cannot handle rotations or local varying deformations over the image. We have developed a fully automatic algorithm that provides fo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of X-ray science and technology
دوره 11 3 شماره
صفحات -
تاریخ انتشار 2003