Molecular weight and ionic strength dependence of fluorescence intensity of the Calcofluor/b-glucan complex in flow-injection analysis

نویسندگان

  • Sanghoon Kim
  • George E. Inglett
چکیده

The flow-injection analysis (FIA) method has long been used for the quantitative determination of b-glucans. FIA makes use of the enhanced fluorescence produced when b-glucan forms complexes with Calcofluor. For successful application of this analysis method, the lowest molecular weight (MW) in the sample has to be higher than a critical MW below which the fluorescence intensity of the complex becomes weaker. Fluorescence measurements reveal that the fluorescence intensity of the Calcofluor/b-glucan complex is strongly dependent on the ionic strength of the solution. At high ionic strength, fluorescence intensity is high and critical MW is low. At low ionic strength, on the other hand, fluorescence intensity is low and critical MW is high. Turbidity measurement shows that Calcofluor/b-glucan complex forms aggregates in the solution and the rate of aggregate formation depends on the MW of b-glucan and concentration of Calcofluor. This study indicates that the FIA method has to be used with solutions of high ionic strength and a high Calcofluor to b-glucan ratio to broaden the applicable MW range of b-glucan analysis. Application of FIA method to the analysis of b-glucan in oat products turns out to be successful as confirmed by comparison with conventional enzymatic analysis. Published by Elsevier Inc.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Barley and Oat β-Glucan Content Measured by Calcofluor Fluorescence in a Microplate Assay

Of the various components of barley and oats, one constituent of the cereal cell wall, (1→3,1→4)-β-D-glucan (β-glucan), is important to a wide range of interests. Malting barley breeders strive to develop lines that modify well, yielding malts with low soluble β-glucan levels in Congress worts (less than the American Malting Barley Association guidelines of 100–120 ppm) (http:// www.ambainc.org...

متن کامل

Ionic Strength Dependence of Formation Constants: Complexation of Dioxouranium (VI) with Aspartic Acid

The dependence on ionic strength of protonation of L-aspartic acid and its complexation withdioxouranium(VI) is reported in sodium perchlorate solution as a background salt. The measurementshave been performed at 25 ± 0.1 °C and various ionic strengths in the range 0.1 to 1.0 mol dm-3, using acombination of potentiometric and spectrophotometric techniques. The overall analysis of the present an...

متن کامل

Ionic str4ength dependence of formation constants, complexation of Glycine with dioxouranium (VI) Ion

The dependence on ionic strength of protonation of glycine and its complexation with dioxouranium (VI) is reported in sodium perchlorate and sodium chloride solutions as background salts. The measurements have been performed at 25±0.1°C and various ionic strengths in the range 0.1 to 1.0 mol , using a combination of potentiometric and spectrophotometric techniques. The overall analysis  of the ...

متن کامل

FLOW INJECTIOW DETERMINATION OF FLUORIDE BY MURTN-ALUMINUM REAGEM WITH SPECTROEUORIMIETRIC DETECTION

A flow injection system is reported for the determination of fluoride based on its effects on the fluorescence intensity of Al-morin complex at pH 3.0 in ethanol-warn mixture. The effect of important parameters such as excitation and emission wavelengths, pH, reagents concenkations, flow rate of the carrier stream, sample injection volume, time of measurepent and interferences are reported. ...

متن کامل

Determination of Methotrexate in Biological Fluids and a Parenteral Injection Using Terbium-Sensitized Method

A new sensitive, simple and rapid method for determination of methotrexate (MTX) was developed based on quenching effects of MTX on the fluorescence intensity of Tb3+-1,10-phenanthroline complex. The fluorescence intensity was measured with excitation wavelength of 300 nm and emission wavelength of 545 nm and the quenched fluorescence intensity is proportional to the concentration of MTX in Tris...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006