Filtering point spread function in backprojection cone-beam CT and its applications in long object imaging.
نویسندگان
چکیده
In backprojection cone-beam CT the cone-beam projection images are first filtered, then 3D backprojected into the object space. In this paper the point spread function (PSF) for the filtering operation is studied. For the cases where the normalization matrix is a constant, i.e. all integration planes intersect the scan path the same number of times, the derivation of the PSF is extended to the general case of limited angular range for the Radon line integrals. It is found that the 2D component of the PSF can be reduced to the form of space-variant 1D Hilbert transforms. The application of the PSF to a number of aspects in long object imaging will be discussed.
منابع مشابه
A differentiable Shepp-Logan phantom and its applications in exact cone-beam CT.
Recently, several exact cone-beam reconstruction algorithms, such as the generalized filtered-backprojection (FBP) and backprojection-filtration (BPF) methods, have been developed to solve the long object problem. Although the well-known 3D Shepp-Logan phantom (SLP) is often used to validate these algorithms, it is deficient due to the discontinuity of the SLP. In this paper, we first construct...
متن کاملKatsevich-Type Algorithms for Variable Radius Spiral Cone-Beam CT
To solve the long object problem, an exact and efficient algorithm has been recently developed by Katsevich. While the Katsevich algorithm only works with standard helical cone-beam scanning, there is an important need for nonstandard spiral cone-beam scanning. Specifically, we need a scanning spiral of variable radius for our newly proposed electron-beam CT/micro-CT prototype. In this paper, f...
متن کاملCone-beam reconstruction by backprojection and filtering.
A new analytical method for tomographic image reconstruction from cone-beam projections acquired on the source orbits lying on a cylinder is presented. By application of a weighted cone-beam backprojection, the reconstruction problem is reduced to an image-restoration problem characterized by a shift-variant point-spread function that is given analytically. Assuming that the source is relativel...
متن کاملAdvanced single-slice rebinning in cone-beam spiral CT: Theoretical considerations and medical applications
The advanced single–slice rebinning algorithm (ASSR) is a highly accurate and efficient approximative algorithm for cone–beam spiral CT that a) yields high image quality even at large cone angles, b) makes use of available 2D backprojection algorithms/hardware and c) allows for sequential data processing. It uses virtual R–planes (reconstruction planes) that are tilted to optimally fit 180 spir...
متن کاملExact Interior Reconstruction with Cone-Beam CT
Using the backprojection filtration (BPF) and filtered backprojection (FBP) approaches, respectively, we prove that with cone-beam CT the interior problem can be exactly solved by analytic continuation. The prior knowledge we assume is that a volume of interest (VOI) in an object to be reconstructed is known in a subregion of the VOI. Our derivations are based on the so-called generalized PI-se...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physics in medicine and biology
دوره 47 15 شماره
صفحات -
تاریخ انتشار 2002