INTRODUCTION Patients in underdeveloped nations have limited access to life-saving medical technology including cardiac rhythm management (CRM) devices. We evaluated alternative means to provide such technology to this patient population while assessing the safety and efficacy of such a practice. METHODS Patients in the United States with clinical indications for extraction of CRM devices were consented. Antemortem CRM devices were cleaned and sterilized following a protocol established at our institution. Surveillance in vitro cultures were performed for quality assurance. The functional status of pulse generators was tested with a pacing system analyzer to confirm at least 70% battery life. Most generators were transported, in person, to an implanting institution in Nicaragua. Recipients with a Class I indication for CRM implantation, and meeting economical criteria set forth, were consented for implantation of a recycled device. RESULTS Between 2003 and 2009, implantation was performed in 17 patients with an average age of 42.1 ± 20.3 years. Of the 17 patients, nine were male and eight were female. Mean follow-up was 68 ± 38 months. Device evaluation occurred prior to discharge, 4 weeks post implantation, and every 6 months thereafter. There were three deaths during the follow-up period secondary to myocardial infarction, stroke, and heart failure. Hematoma formation occurred in one patient. No infections, early battery depletion, or device malfunction were identified during follow-up. CONCLUSIONS Our case series is the longest follow-up of recipients of recycled antemortem CRM devices. Our findings support the feasibility and safety of this alternative acquisition of life-saving technology.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

European Heart Rhythm Association Guidance Document on cardiac rhythm management product performance.

The comparatively large number of field safety corrective actions (FSCAs) recently issued by different device manufacturers has attracted attention to cardiac rhythm management (CRM) device performance. It has also prompted questions as to the basis for the scientifically proven efficacy of implantable cardioverter-defibrillators, pacemakers, and cardiac resynchronization therapy devices. The b...

متن کامل

Initial documented rhythm as a predictor of survivalto-discharge rate after in-hospital cardiac arrest in a tertiary care referral institute, South India: an observational study

Objective: Survival-to-discharge rates following in-hospital cardiac arrest (IHCA) patients remain significantly low. The use of initial documented cardiac rhythm as predictor of Survival-to-discharge is still unclear. This study aimed to assess whether the initial documented rhythm can be used as a predictor of survival-to-discharge following IHCA in an emergency department of the tertiary car...

متن کامل

Regional variations in baseline characteristics of cardiac rhythm device recipients: The PANORAMA observational cohort study☆

Background The PANORAMA study was designed to collect concurrent data on subjects from different worldwide regions implanted with CRM devices. Methods In this prospective, multi-center study, we analyzed baseline data on 8586 subjects implanted with CRM devices with no additional selection criteria (66% pacemaker (IPG), 16% implantable cardiac defibrillators (ICD), 17% cardiac resynchronizati...

متن کامل

A Study of Cerebral Performance Categories Based on Initial Rhythm and Resuscitation Time Following In-Hospital Cardiac Arrest in a State Hospital in Turkey

Background: The cerebral performance category (CPC) score is widely used in research and quality assurance to assess neurologic outcome following cardiac arrest. However, little is known about the results of the CPC in Turkey. Objective: This study aimed to determine whether the CPC is associated with the initial rhythm and resuscitation time following re...

متن کامل

Safety, Efficacy and Clinical Outcome of Direct Stent Implantation

Conventional methods of stenting require predilatation, which potentially increase vessel wall injury and cost of the procedure. In this study, the safety and efficacy of direct AVE-S7 (Medtronic-USA) stent placement were evaluated in 100 patients. Quantitative coronary angiography was performed at the baseline and post-stent. Clinical follow-up was done up to 9 months. In 100 patients (76 male...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Pacing and clinical electrophysiology : PACE

دوره 34 6  شماره 

صفحات  -

تاریخ انتشار 2011