Permanent pacemaker and implantable cardioverter defibrillator infection: a population-based study.

نویسندگان

  • Daniel Z Uslan
  • Muhammad R Sohail
  • Jennifer L St Sauver
  • Paul A Friedman
  • David L Hayes
  • Sarah M Stoner
  • Walter R Wilson
  • James M Steckelberg
  • Larry M Baddour
چکیده

BACKGROUND The incidence of cardiac device infection is not well understood. Bloodstream infection (BSI) in patients with permanent pacemakers or implantable cardioverter-defibrillators (hereafter, defibrillators) may reflect device infection. METHODS Retrospective, population-based cohort study of all adult patients with cardiac devices who resided in Olmsted County, Minnesota, from 1975 to 2004. The medical linkage-system of the Rochester Epidemiology Project and standardized criteria were used to identify all cases of BSI and device infection. The incidence of device infection was calculated with person-years of follow-up after device implantation. RESULTS A total of 1524 patients with cardiac devices were included in the cohort. Total person-time of follow-up was 7578 years. The incidence of definite device infection was 1.9 per 1000 device-years (95% confidence interval [CI], 1.1-3.1). The incidence of pocket infection without BSI was 1.37 per 1000 device-years (95% CI, 0.62-3.05), and pocket infection with BSI or device-related endocarditis 1.14 per 1000 device years (95% CI, 0.47-2.74). The cumulative probability of device infection was higher among patients with defibrillators compared with those with pacemakers, P<.001. Twelve (54.6%) of 22 cases of Staphylococcus aureus BSI had definite or possible cardiac device infection vs 3 (12.0%) of 25 cases of bloodstream infection due to gram-negative bacilli (P = .004). CONCLUSIONS To our knowledge, this is the first population-based study to describe the incidence of cardiac device infection. Device infection was common during episodes of S aureus BSI. The rate of cardiac device infection was higher in patients with defibrillators than in those with pacemakers.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...

متن کامل

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

Pacemaker and arrhythmias in pediatric patients. An update

Arrhythmias in children are the enemy of any medical emergency. Different mechanisms should be very dangerous in particular for its adaptation mechanisms. Tachyarrhythmias (extrasistols, supraventricular tachycardia SVT, permanent junctional reciprocating tachycardia, atrial flutter, supraventricular tachycardias, ventricular tachycardias). Bradyarrhythmias (atrioventricular blocks) and channel...

متن کامل

Should implantable cardioverter-defibrillators and permanent pacemakers in patients with terminal illness be deactivated? Deactivating Implantable Cardioverter-Defibrillators and Permanent Pacemakers in Patients With Terminal Illness

The recently published 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities1 include a discussion of ethical issues surrounding the deactivation of pacemakers, implanted cardioverter-defibrillator (ICDs), and CRT devices in patients who are terminally ill. The authors rightly note that most clinicians make an ethical distinction between deactivating an ICD and deactivating a...

متن کامل

The effect of education based on Orem’s self-care model on emotional reactions in patients with Implantable Cardioverter Defibrillator (ICD)

Abstract Aim. The purpose of this study was to examine the effect of education based on Orem’s self-care model on emotional reactions in people with Implantable Cardioverter Defibrillator (ICD). Background. ICD shock is unpredictable and associated with physical pain. After receiving shock, some patients find serious psychological problems such as anxiety, depression and stress. According to Or...

متن کامل

A Rare Cause of Cardiac Tamponade: Left Ventricular Pacemaker Malposition

The malpositioning of a pacemaker lead is an uncommon and under-reported complication of pacemaker/Automated Implantable Cardioverter-Defibrillator (AICD) placement. It can be associated with complications such as pericardial effusions and tamponade. We describe a case of an elderly woman who developed cardiac tamponade after inadvertent placement of a permanent pacing lead in the left ventricl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Archives of internal medicine

دوره 167 7  شماره 

صفحات  -

تاریخ انتشار 2007