Long-stem revision prosthesis for salvage of failed fixation of extracapsular proximal femoral fractures.

نویسندگان

  • Rory J Sharvill
  • Nicholas A Ferran
  • Huw G Jones
  • Stephen A Jones
چکیده

A retrospective review was made of radiographs and case notes of patients with failed fixation of extracapsular proximal femoral fractures subsequently managed with long-stem revision arthroplasty. Follow-up radiographs, objective scoring, mobility, and complications were assessed. Twenty five hips were managed with long-stem hip arthroplasty in 24 patients with a mean age of 73 years. The mean follow-up was 24 months. Patients received uncemented acetabular components and long-stem uncemented femoral implants. Complications included two intraoperative femoral fractures which were strut-grafted, three wound infections (one required washout), and one recurrent dislocation managed conservatively. Average postoperative Oxford Hip score was 29. We report a low complication rate and no specific implant related problems, with good functional outcome as evidenced by the outcome scores and mobility status following salvage arthroplasty.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Challenges of Plate Fixation for Vancouver Type-C Fractures after a Well-Fixed Hip Arthroplasty Femoral Stem

The fixation of distal femoral fractures (Vancouver type-C fractures) following a well-fixed hip arthroplasty femoral stem has become a challenging issue for orthopedic surgeons due to the inter-prosthetic biomechanical effects such as negative, positive, and torsional strain. Surgeons have applied a range of constructs to overcome these difficulties. To minimize the risk of inter-prosthetic fr...

متن کامل

Reverse distal femoral locking compression plate a salvage option in nonunion of proximal femoral fractures

BACKGROUND When primary fixation of proximal femoral fractures with implants fails, revision osteosynthesis may be challenging. Tracts of previous implants and remaining insufficient bone stock in the proximal femur pose unique problems for the treatment. Intramedullary implants like proximal femoral nail (PFN) or surface implants like Dynamic Condylar Screw (DCS) are few of the described impla...

متن کامل

Salvage of failed trochanteric and subtrochanteric fractures using a distally fixed, modular, uncemented hip revision stem

BACKGROUND AND PURPOSE Treatment options for failed internal fixation of hip fractures include prosthetic replacement. We evaluated survival, complications, and radiographic outcome in 30 patients who were operated with a specific modular, uncemented hip reconstruction prosthesis as a salvage procedure after failed treatment of trochanteric and subtrochanteric fractures. PATIENTS AND METHODS ...

متن کامل

Periprosthetic Femoral Fracture With Broken Implant Insitu: - A Treatment Prospect

INTRODUCTION Fractures involving bones containing a component of a prosthetic joint are becoming more common. The causation is multifactorial but most of these injuries are associated with trivial trauma. The options available for operative management of these fractures include internal fixation of the fracture alone, fixation of the fracture with revision of the prosthesis, and reconstruction ...

متن کامل

Periprosthetic femoral fractures treated with a modular distally cemented stem.

PURPOSE To assess the treatment outcome of revision hip arthroplasty for Vancouver type B3 periprosthetic femoral fractures using a modular distally cemented stem. METHODS 22 men and 14 women (37 hips) aged 66 to 79 (mean, 70) years underwent revision hip arthroplasty for Vancouver type B3 periprosthetic femoral fractures. The indication for surgery was periprosthetic fracture with stem loose...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Acta orthopaedica Belgica

دوره 75 3  شماره 

صفحات  -

تاریخ انتشار 2009