Continuous retinal vessel diameter measurements: the future in retinal vessel assessment?

نویسندگان

  • Rebekka Heitmar
  • Andrew D Blann
  • Robert P Cubbidge
  • Gregory Y H Lip
  • Doina Gherghel
چکیده

PURPOSE To establish an alternative method, sequential and diameter response analysis (SDRA), to determine dynamic retinal vessel responses and their time course in serial stimulation compared with the established method of averaged diameter responses and standard static assessment. METHODS SDRA focuses on individual time and diameter responses, taking into account the fluctuation in baseline diameter, providing improved insight into reaction patterns when compared with established methods as delivered by retinal vessel analyzer (RVA) software. SDRA patterns were developed with measurements from 78 healthy nonsmokers and subsequently validated in a group of 21 otherwise healthy smokers. Fundus photography and retinal vessel responses were assessed by RVA, intraocular pressure by contact tonometry, and blood pressure by sphygmomanometry. RESULTS Compared with the RVA software method, SDRA demonstrated a marked difference in retinal vessel responses to flickering light (P < 0.05). As a validation of that finding, SDRA showed a strong relation between baseline retinal vessel diameter and subsequent dilatory response in both healthy subjects and smokers (P = 0.001). The RVA software was unable to detect this difference or to find a difference in retinal vessel arteriovenous ratio between smokers and nonsmokers (P = 0.243). However, SDRA revealed that smokers' vessels showed both an increased level of arterial baseline diameter fluctuation before flicker stimulation (P = 0.005) and an increased stiffness of retinal arterioles (P = 0.035) compared with those in nonsmokers. These differences were unrelated to intraocular pressure or systemic blood pressure. CONCLUSIONS SDRA shows promise as a tool for the assessment of vessel physiology. Further studies are needed to explore its application in patients with vascular diseases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extracting Vessel Centerlines From Retinal Images Using Topographical Properties and Directional Filters

In this paper we consider the problem of blood vessel segmentation in retinal images. After enhancing the retinal image we use green channel of images for segmentation as it provides better discrimination between vessels and background. We consider the negative of retinal green channel image as a topographical surface and extract ridge points on this surface. The points with this property are l...

متن کامل

Assessing vascular function using dynamic retinal diameter measurements: a new insight on the endothelium.

Reliable assessment of endothelial function is important for the diagnosis, risk prediction and treatment-monitoring in cardiovascular disease. Numerous techniques exist such as flow mediated dilation (FMD) (1, 2), venous occlusion plethysmography (3, 4), pulse-wave analysis (5) and laser Doppler iontophoresis (6). Individually, each technique provides some information on the state of endotheli...

متن کامل

Comparison of Common Retinal Vessel Caliber Measurement Software and a Conversion Algorithm

PURPOSE To compare three commonly used retinal vessel caliber measurement software systems, and propose an algorithm for conversion between measurement systems. METHODS We used 120 retinal photographs to evaluate the agreement between three commonly used software (Retinal Analysis [RA], Integrative Vessel Analysis [IVAN], and Singapore I Vessel Assessment [SIVA]). Bland-Altman plots were used...

متن کامل

Retinal vessel diameters and reactivity in diabetes mellitus and/or cardiovascular disease

BACKGROUND Retinal vessel calibre and vascular dilation/constriction in response to flicker light provocation may provide a measure distinguishing patients suffering from diabetes mellitus and/or cardiovascular disease. METHODS One hundred and sixteen age and sex matched patients with diabetes mellitus (DM), cardiovascular disease (CVD) and both DM and CVD (DM + CVD) underwent systemic and in...

متن کامل

Influence of flicker frequency on flicker-induced changes of retinal vessel diameter.

PURPOSE To investigate the effect of diffuse luminance flicker of different frequencies on retinal vessel diameter in the human eye. METHODS Nine healthy subjects participated in the study. A retinal vessel analyzer (RVA; Zeiss, Jena, Germany) was modified to allow for continuous measurement of vessel diameter during flicker stimulation. With this technique, the light used for measurement of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 51 11  شماره 

صفحات  -

تاریخ انتشار 2010