A Novel Method to Improve Single Phase Reconstruction Quality from Conventional CBCT

ثبت نشده
چکیده

Innovation/Impact: We consider our 4DCBCT reconstruction algorithm to be innovative, because of two reasons. One is that it works on conventional CBCT dataset and does not demand elongated scanning time or excessive patient dose. The other one is the improved image quality compared with traditional retrospective sorting technique, which reconstructs from sorted same phase projections and are usually with artifacts due to undersampling.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

AbstractID: 14214 Title: A novel scatter reduction and correction method to improve cone-beam CT (CBCT) image quality

ID: 14214 Title: A novel scatter reduction and correction method to improve cone-beam CT (CBCT) image quality Purpose: To develop a novel scatter reduction and correction method to improve the CBCT image quality for IGRT applications. Method and Materials: A one-dimensional grid composed of lead with equal interspacing was positioned between the x-ray source and the imaging object during CBCT a...

متن کامل

Autoadaptive phase-correlated (AAPC) reconstruction for 4D CBCT.

PURPOSE Kilovoltage cone-beam computed tomography (CBCT) is widely used in image-guided radiation therapy for exact patient positioning prior to the treatment. However, producing time series of volumetric images (4D CBCT) of moving anatomical structures remains challenging. The presented work introduces a novel method, combining high temporal resolution inside anatomical regions with strong mot...

متن کامل

I. INTRODUCTION Advances in model-based iterative reconstruction (IR) methods for x-ray CT and cone-beam CT (CBCT) imaging

C-arm cone-beam CT offers great potential in image-guided interventions, but conventional analytic reconstruction methods are associated with limited image quality, particularly for soft-tissue imaging. While model-based iterative reconstruction (IR) methods improve image quality and/or reduce radiation dose, long reconstruction time limits utility in clinical workflow. Additionally, in contras...

متن کامل

Low-Dose and Scatter-Free Cone-Beam CT Imaging Using a Stationary Beam Blocker in a Single Scan: Phantom Studies

Excessive imaging dose from repeated scans and poor image quality mainly due to scatter contamination are the two bottlenecks of cone-beam CT (CBCT) imaging. Compressed sensing (CS) reconstruction algorithms show promises in recovering faithful signals from low-dose projection data but do not serve well the needs of accurate CBCT imaging if effective scatter correction is not in place. Scatter ...

متن کامل

A Novel Method for Estimation of The Fundamental Parameters of Distorted Single Phase Signals

This paper proposes a new method for parameter estimation of distorted single phase signals, through an improved demodulation-based phase tracking incorporated with a frequency adaptation mechanism. The simulation results demonstrate the superiority of the proposed method compared to the conventional SOGI (Second-Order Generalized Integrator)-based approach, in spite of the dc-offset and harmon...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013