Optimizing glenoid component position using three-dimensional computed tomography reconstruction.

نویسندگان

  • Heinz R Hoenecke
  • Juan C Hermida
  • Nicholas Dembitsky
  • Shantanu Patil
  • Darryl D D'Lima
چکیده

Glenoid implant design and alignment are critical to the success of shoulder arthroplasty. Computer-aided design models of 3 glenoid implant designs (keel, standard pegs, and modified pegs) were virtually implanted into 3-dimensional computed tomography-reconstructed models of 40 normal scapulae. The incidence of perforation on 3-dimensional computed tomography preoperative templating varied from 8% to 18% for the 3 models. Malalignment of the implants in retroversion was better tolerated than anteversion and varied with implant design. Tolerance for medialization of the implant to correct for glenoid wear was limited (range, 0 degrees-18 degrees ) and varied with implant design. The modified peg design had the lowest incidence of perforation, the greatest tolerance for malalignment, and the ability to correct for glenoid wear effects. These results emphasize the need for accurate preoperative templating and for developing alignment guides or surgical navigation tools for shoulder arthroplasty and may be used to improve implant fixation designs.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two-dimensional glenoid version measurements vary with coronal and sagittal scapular rotation.

BACKGROUND Accurate analysis of osseous glenoid morphology is important in treating glenohumeral arthritis and instability. Two-dimensional computed tomography scans are used to evaluate glenoid alignment. Accuracy of this method is dependent on the angle of axial reconstruction in relation to the position of the scapula. The purpose of this study was to investigate the effect of scapular rotat...

متن کامل

Three-dimensional reconstruction of New Zealand rabbit antebrachium by multidetector computed tomography

The aim of this study was to reveal biometric peculiarities of New Zealand white rabbit antebrachium (radius and ulna) by means of three-dimensional (3D) reconstruction of multidetector computed tomography (MDCT) images. Under general anesthesia, the antebrachiums of a total of sixteen rabbits of both sexes were scanned with a general diagnostic MDCT. Biometric measurements of the reconstructed...

متن کامل

Assessment of Cone-Beam Computed Tomography (CBCT) Findings in Facial Asymmetric Patients

Introduction: Due to the complexity of facial asy-mmetry, the diagnosis of different aspects of asymmetry via conventional radiographs is not precise. In this study, we investigated findings of facial asymmetry by using cone- beam computed tomography (CBCT) images. Materials and Methods: In this descriptive study, we evaluated CBCT findings of 18 patients i.e. a group of 14 females and 4 males ...

متن کامل

Cadaveric and three-dimensional computed tomography study of the morphology of the scapula with reference to reversed shoulder prosthesis

PURPOSE The purpose of this study is to analyze the morphology of the scapula with reference to the glenoid component implantation in reversed shoulder prosthesis, in order to improve primary fixation of the component. METHODS Seventy-three 3-dimensional computed tomography of the scapula and 108 scapular dry specimens were analyzed to determine the anterior and posterior length of the glenoi...

متن کامل

Three-dimensional measurement method of arthritic glenoid cavity morphology: feasibility and reproducibility.

INTRODUCTION Glenoid component loosening is the main complication of total shoulder arthroplasty. Better knowledge of the arthritic glenoid cavity anatomy can help in developing new implants and techniques. The goal of this study was to describe and validate the reproducibility of a CT scan-based, 3D measurement method used to describe various parameters characterizing arthritic glenoid cavity ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of shoulder and elbow surgery

دوره 17 4  شماره 

صفحات  -

تاریخ انتشار 2008