Development of an NDIR CO2 Sensor-Based System for Assessing Soil Toxicity Using Substrate-Induced Respiration

نویسندگان

  • Jasmeen Kaur
  • Viacheslav I. Adamchuk
  • Joann K. Whalen
  • Ashraf A. Ismail
چکیده

The eco-toxicological indicators used to evaluate soil quality complement the physico-chemical criteria employed in contaminated site remediation, but their cost, time, sophisticated analytical methods and in-situ inapplicability pose a major challenge to rapidly detect and map the extent of soil contamination. This paper describes a sensor-based approach for measuring potential (substrate-induced) microbial respiration in diesel-contaminated and non-contaminated soil and hence, indirectly evaluates their microbial activity. A simple CO2 sensing system was developed using an inexpensive non-dispersive infrared (NDIR) CO2 sensor and was successfully deployed to differentiate the control and diesel-contaminated soils in terms of CO2 emission after glucose addition. Also, the sensor system distinguished glucose-induced CO2 emission from sterile and control soil samples (p ≤ 0.0001). Significant effects of diesel contamination (p ≤ 0.0001) and soil type (p ≤ 0.0001) on glucose-induced CO2 emission were also found. The developed sensing system can provide in-situ evaluation of soil microbial activity, an indicator of soil quality. The system can be a promising tool for the initial screening of contaminated environmental sites to create high spatial density maps at a relatively low cost.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment the effect of Slope aspect and position on some soil microbial indices in rangeland and forest

Extended abstract   Introduction   Topography is one of the effective factors in soil formation and development. Topographical features such as slope aspect and position, by affecting soil temperature, evaporation capacity, soil moisture content, soil organic matter, precipitation, movement, and accumulation of soil solution can impress soil microbial properties. For investigating the ...

متن کامل

A High-Precision NDIR CO2 Sensing Module for ZigBee Applications

NDIR-based CO2 sensor is commonly used in the field of environmental monitoring due to relatively high accuracy compared with that of a chemical CO2 gas sensor. This paper presents a wireless sensing system with a low-cost Non-Dispersive InfraRed (NDIR) sensor module used to determine gas concentration in a remote air quality monitoring system. Unlike the chemical CO2 gas sensor, the proposed s...

متن کامل

Assessment of the effects of phenanthrene and its nitrogen heterocyclic analogues on microbial activity in soil

Microbes are susceptible to contaminant effects, and high concentrations of chemical in soil can impact on microbial growth, density, viability and development. As a result of relative sensitivity of microbes to contaminants, toxicity data are important in determining critical loads or safe levels for contaminants in soil. Therefore the aim of this study was to assess the impact of phenanthrene...

متن کامل

A Simple Method for Measuring Co2 in a Continuous Air-flow System: Modifications to the Substrate-induced Respiration Technique

A simple, inexpensive method for measurement of respiration (CO, evolution) under a continuous air-flow was calibrated against an i.r. gas analyzer. Regression equations were developed to apply the method to general soil respiration measurement in the laboratory. The substrate-induced respiration technique was modified. By using 120% PWHC as a standard soil water condition during incubation, in...

متن کامل

Cmos-based Luminescent Co2 Sensor

In this work, we demonstrate a portable optical CO2 sensor using CMOS image sensing with polarization signal isolation. Luminescent CO2 detection methods generally exhibit faster response time and increased sensitivity over the established commercial sensors (NDIR, electrochemical), but require bulky and expensive spectrophotometry equipment which confines them to a lab. Components used in our ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2015