Concurrent correction of geometric distortion and motion using the map-slice-to-volume method in echo-planar imaging.
نویسندگان
چکیده
The accuracy of measuring voxel intensity changes between stimulus and rest images in fMRI echo-planar imaging (EPI) data is severely degraded in the presence of head motion. In addition, EPI is sensitive to susceptibility-induced geometric distortions. Head motion causes image shifts and associated field map changes that induce different geometric distortion at different time points. Conventionally, geometric distortion is "corrected" with a static field map independently of image registration. That approach ignores all field map changes induced by head motion. This work evaluates the improved motion correction capability of mapping slice to volume with concurrent iterative field corrected reconstruction using updated field maps derived from an initial static field map that has been spatially transformed and resampled. It accounts for motion-induced field map changes for translational and in-plane rotation motion. The results from simulated EPI time series data, in which motion, image intensity and activation ground truths are available, show improved accuracy in image registration, field corrected image reconstruction and activation detection.
منابع مشابه
Concurrent Geometric Distortion Correction in Mapping Slice-to-volume (MSV) Motion Correction of fMRI Time Series
D. Yeo, J. A. Fessler, B. Kim Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, MI, United States, Radiology, University of Michigan Medical School, Ann Arbor, MI, United States Introduction: The accuracy of measuring voxel intensity changes between stimulus and rest images in fMRI echo-planar imaging (EPI) data, from which brain activation maps are computed, is se...
متن کاملEffect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI
Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...
متن کاملGeometric distortion correction in echo volumar imaging
Introduction: Echo volumar imaging (EVI) is a 3D extension of echo-planar imaging (EPI) that allows data from an entire volume to be acquired following a single excitation. However, only a few studies to date have applied EVI to functional MRI (fMRI) due to its high sensitivity to field-inhomogeneity induced distortions. In this study, we extend two EPI distortion correction techniques to EVI: ...
متن کاملImage distortion correction in fMRI: A quantitative evaluation.
A well-recognized problem with the echo-planar imaging (EPI) technique most commonly used for functional magnetic resonance imaging (fMRI) studies is geometric distortion caused by magnetic field inhomogeneity. This makes it difficult to achieve an accurate registration between a functional activation map calculated from an EPI time series and an undistorted, high resolution anatomical image. A...
متن کاملFabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...