Fat-suppressed MR Imaging of the Spine for Metal Artifact Reduction at 3T: Comparison of STIR and Slice Encoding for Metal Artifact Correction Fat-suppressed T2-weighted Images
نویسندگان
چکیده
PURPOSE To compare short tau inversion recovery (STIR) images with slice encoding for metal artifact correction (SEMAC)-corrected magnetic resonance imaging (MRI) of spectral presaturation with inversion recovery (SPIR) or inversion recovery (IR) at 3T in patients with metallic spinal instrumentation. METHODS Following institutional review board's approval, 71 vertebrae with interbody fixation in 26 patients who underwent transpedicular spondylodesis with spinal metallic prostheses were analyzed with SEMAC spinal MRI. All the fixated vertebrae were examined with STIR, and 41 vertebrae of 15 patients were scanned with SEMAC-SPIR T2-weighted MRI. The remaining 30 vertebrae of 11 patients were scanned with SEMAC-IR T2-weighted MRI. Two musculoskeletal radiologists compared the image sets and qualitatively analyzed the images with a five-point scale that included artifact reduction around the metallic implant and visualization of the rod and pedicle. Quantitative assessments were performed by calculating the signal intensity ratio of the fixated vertebra and non-metallic vertebra and by calculating the signal-to-noise ratios (SNRs) of the vertebrae. A paired t-test was used for the statistical analyses. RESULTS The SEMAC-IR MRI had a significant decrease in the metallic artifact area (P < 0.05), while the SEMAC-SPIR MRI yielded significantly increased artifact areas (P < 0.05). However, the signal intensity ratios (i.e., metal-induced signal pile-up) were not significantly different (P > 0.05) between the STIR and SEMAC MRI. The SNR of the SEMAC MRI was significantly lower than the SNR of the STIR (P < 0.05). The metal artifact reduction scores were significantly higher in the SEMAC-SPIR MRI (P < 0.05). CONCLUSION Despite the relatively larger artifact size and lower SNRs, the SEMAC-SPIR MRI was superior to the other types of fat-suppressed MRI of SEMAC-IR or T2-weighted STIR MRI. However, the drawbacks of high signal pile-up, large artifact size, and relatively low SNRs require further investigation to determine the best method for fat-suppressed MRI of metallic implants.
منابع مشابه
Fat-Suppressed and Distortion-Corrected MRI Near Metallic Implants
Introduction: The use of orthopedic implants including joint replacements and fixation devices is increasingly common, necessitating follow-up evaluation to assess possible complications such as loosening or infection. Due to metal-induced distortion and other artifacts on conventional MRI, follow-up is often limited to Xray images. With additional encoding and parallel imaging, MR images with ...
متن کاملEvaluation of Metal Artifact Reduction software in Computed Tomography
Introduction: The image quality of computed tomography (CT) can be seriously lowered by metal implants of patients. These implants are known to exert a significant impact on diagnostic accuracy due to artifacts. The current study aimed to assess the usefulness of Metal Artifact Reduction (MAR) software in the reduction of metal artifacts, in comparison to iterative rec...
متن کاملFat-suppressed MR of the orbit and cavernous sinus: comparison of fast spin-echo and conventional spin-echo.
PURPOSE To compare T2-weighted fat-suppressed fast spin-echo imaging with fat-suppressed conventional spin-echo imaging in the detection of normal intraorbital and pericavernous anatomy and orbital disease, and to determine the efficacy of fat saturation with T2-weighted fast spin-echo imaging of the cavernous sinus. METHODS Contrast-to-noise ratios of normal intraorbital anatomy were calcula...
متن کاملView-Angle Tilting and Slice-Encoding Metal Artifact Correction for Artifact Reduction in MRI: Experimental Sequence Optimization for Orthopaedic Tumor Endoprostheses and Clinical Application
BACKGROUND MRI plays a major role in follow-up of patients with malignant bone tumors. However, after limb salvage surgery, orthopaedic tumor endoprostheses might cause significant metal-induced susceptibility artifacts. PURPOSES To evaluate the benefit of view-angle tilting (VAT) and slice-encoding metal artifact correction (SEMAC) for MRI of large-sized orthopaedic tumor endoprostheses in a...
متن کاملArtifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 15 شماره
صفحات -
تاریخ انتشار 2016