A micromachined interface for airborne sample-to-liquid transfer and its application in a biosensor system.
نویسندگان
چکیده
A novel micromachined interface for airborne sample-to-liquid adsorption and droplet-to-liquid transfer was designed and fabricated. It enables a robust sheet liquid flow serving as an adsorption site. The interface was characterised for flow and pressure properties and tested successfully for the transfer/adsorption of different samples. A qualitative theoretical model of the device characteristics is presented. We also used the interface to introduce a novel method and system for fast detection of dust- and vapour-based narcotics and explosives traces. The microfluidic vapour-to-liquid adsorption interface was coupled to a set of downstream QCM sensors. The system was tested successfully, with 50 ng cocaine samples rendering 15 Hz frequency shifts and with 100 ng heroine samples rendering 50 Hz frequency shifts. Gravitation invariance of the open liquid interface was demonstrated successfully, with the interface mounted upside down as well as vertically. The detection time was reduced to half of the time needed in previous systems. Machine size, weight and cost were reduced.
منابع مشابه
Fabrication of a Voltammetric Biosensor in Combination with Enzyme-linked Immunosorbent Assay to Detect Aflatoxin M1 in Milks
Background and Objectives: Aflatoxin M1 is one the most important mycotoxin contaminants of milks. Various methods have been described to detect aflatoxins in milks, including chromatography, enzyme-linked immunosorbent assay and colorimetry. Regarding high sensitivity of electrochemical sensor based methods, the aim of the present study was to fabricate an accurate sensitive voltametric biosen...
متن کاملThe Effect of pH on the Liquid-liquid Equilibrium for a System Containing Polyethylene Glycol Di-methyl Ether and Tri-potassium Citrate and its Application for Acetaminophen Separation
In this work liquid-liquid equilibrium for aqueous two phase system composed of polyethylene glycol di-methyl ether and tri-potassium citrate at different medium pH values (6.00, 7.00 and 8.00) and 298.15 K was studied. The obtained results show that two phase area expanded with an increasing of pH values. The performances of the Merchuk and semi-empirical equations were tested in correlating t...
متن کاملInvestigating the Effects of Mass Transfer and Mixture Non-Ideality on Multiphase Flow Hydrodynamics Using CFD Methods
A numerical framework has been proposed to model the interacting effects of mixture non-ideality and mass transfer on hydrodynamics of a multiphase system using CFD methods.Mass transfer during condensation and vaporization is modeled by chemical potential at the liquid-vapor interface. Species mass transfers are related to the diffusion at the interface which in turn is related to the conc...
متن کاملEVALUATION OF PRESSURE EFFECT ON HEAT TRANSFER COEFFICIENT AT THE METAL- MOLD INTERFACE FOR CASTING OF A356 AL ALLOY
Abstract: During solidification and casting in metallic molds, the heat flow is controlled by the thermal resistance at the casting-mold interface. Thus heat transfer coefficient at the metal- mold interface has a predominant effect on the rate of heat transfer. In some processes such as low pressure and die-casting, the effect of pressure on molten metal will affect the rate of heat transfer a...
متن کاملEvaluation of Different Functionalized CNTs for Development of Choline Amperometric Biosensor
Choline oxidase (ChOx) was chosen as a model enzyme for evaluating the performance of CNTs’ functional groups for development of enzyme electrodes. CNTs were functionalized with carboxylic acid, amine or amide groups. Carboxylic acid, amine and amide functionalized CNTs were obtained by acid treatment, ethylenediamine or tetraethylenepentamine chemically modification and ammonia plasma treatmen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Lab on a chip
دوره 6 12 شماره
صفحات -
تاریخ انتشار 2006