Fully automatic nonrigid registration-based local motion estimation for motion-corrected iterative cardiac CT reconstruction.

نویسندگان

  • Alfonso A Isola
  • Michael Grass
  • Wiro J Niessen
چکیده

PURPOSE Cardiac computed tomography is a rapidly emerging technique for noninvasive diagnosis of cardiovascular diseases. Nevertheless, the cardiac motion continues to be a limiting factor. Electrocardiogram-gated cardiac computed tomography reconstruction methods yield excellent results, but these are limited in their temporal resolution due to the mechanical movement of the gantry, and lead to residual motion blurring artifacts. If the motion of the cardiac region of interest is determined, motion compensated gated reconstructions can be applied to reduce motion artifacts. In this paper it is shown that elastic image registration methods can be an accurate solution to determine the cardiac motion. A method, which combines elastic registration and iterative computed tomography reconstruction methods delivering motion-corrected images of a chosen cardiac region of interest, is introduced. METHODS Using a gated four-dimensional region of interest image data set, a fully automatic elastic image registration is applied to recover a cardiac displacement field from a reference phase to a number of phases within the RR interval. Here, a stochastic optimizer and multiresolution approach are adopted to speed up the registration process. Subsequently, motion-compensated iterative reconstruction using the determined motion field is carried out. For the image representation volume-adapted spherical basis functions (blobs) are used to take the volume change caused by a divergent motion vector field into account. RESULTS The method is evaluated on phantom data and on four clinical data sets at a strong cardiac motion phase. Comparing the method to standard gated iterative reconstruction results shows that motion compensation strongly improves the image quality in these phases. A qualitative and quantitative accuracy study is presented for the estimated cardiac motion field. For the first time a blob-volume adaptation is applied on clinical data, and in the case of divergent motion it yields improved image quality. CONCLUSIONS A fully automatic local cardiac motion compensated gated iterative method with volume-adapted blobs is proposed. The method leads to excellent motion-corrected images which outperform nonmotion corrected results in phases of strong cardiac motion. In clinical cases, a volume-dependent blob-footprint adaptation proves to be a good solution to take care of the change in the blob volume caused by a divergent motion field.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cardiac motion-corrected iterative cone-beam CT reconstruction using a semi-automatic minimum cost path-based coronary centerline extraction

In this paper a method which combines iterative computed tomography reconstruction and coronary centerline extraction technique to obtain motion artifact-free reconstructed images of the coronary arteries are proposed and evaluated. The method relies on motion-vector fields derived from a set of coronary centerlines extracted at multiple cardiac phases within the R-R interval. Hereto, start and...

متن کامل

Joint image reconstruction and nonrigid motion estimation with a simple penalty that encourages local invertibility

Motion artifacts are a significant issue in medical image reconstruction. There are many methods for incorporating motion information into image reconstruction. However, there are fewer studies that focus on deformation regularization in motioncompensated image reconstruction. The usual choice for deformation regularization has been penalty functions based on the assumption that tissues are ela...

متن کامل

Nonrigid groupwise registration for motion estimation and compensation in compressed sensing reconstruction of breath-hold cardiac cine MRI.

PURPOSE Compressed sensing methods with motion estimation and compensation techniques have been proposed for the reconstruction of accelerated dynamic MRI. However, artifacts that naturally arise in compressed sensing reconstruction procedures hinder the estimation of motion from reconstructed images, especially at high acceleration factors. This work introduces a robust groupwise nonrigid moti...

متن کامل

Reducing the respiratory motion artifacts in PET cardiology: A simulation study

  Introduction: There are several technical features that make PET an ideal device for the noninvasive evaluation of cardiac physiology. Organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac PET imaging. These motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent les...

متن کامل

Compensation for nonrigid motion using B-spline image registration in simultaneous MR-PET

Introduction Motion correction in PET imaging has been actively researched in the PET community, however obtaining accurate motion estimation is challenging. Motion has been usually estimated from CT images in PET/CT acquisition or from the PET data themselves. However, both modalities have limited accuracy for estimating motion because CT suffers from poor soft tissue contrast while PET has po...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical physics

دوره 37 3  شماره 

صفحات  -

تاریخ انتشار 2010