A bio-telemetric device for measurement of left ventricular pressure-volume loops using the admittance technique in conscious, ambulatory rats.
نویسندگان
چکیده
This paper presents the design, construction and testing of a device to measure pressure-volume loops in the left ventricle of conscious, ambulatory rats. Pressure is measured with a standard sensor, but volume is derived from data collected from a tetrapolar electrode catheter using a novel admittance technique. There are two main advantages of the admittance technique to measure volume. First, the contribution from the adjacent muscle can be instantaneously removed. Second, the admittance technique incorporates the nonlinear relationship between the electric field generated by the catheter and the blood volume. A low power instrument weighing 27 g was designed, which takes pressure-volume loops every 2 min and runs for 24 h. Pressure-volume data are transmitted wirelessly to a base station. The device was first validated on 13 rats with an acute preparation with 2D echocardiography used to measure true volume. From an accuracy standpoint, the admittance technique is superior to both the conductance technique calibrated with hypertonic saline injections, and calibrated with cuvettes. The device was then tested on six rats with 24 h chronic preparation. Stability of animal preparation and careful calibration are important factors affecting the success of the device.
منابع مشابه
A self-calibrating telemetry system for measurement of ventricular pressure-volume relations in conscious, freely moving rats.
Using Bluetooth wireless technology, we developed an implantable telemetry system for measurement of the left ventricular pressure-volume relation in conscious, freely moving rats. The telemetry system consisted of a pressure-conductance catheter (1.8-Fr) connected to a small (14-g) fully implantable signal transmitter. To make the system fully telemetric, calibrations such as blood resistivity...
متن کاملNormal Value of Left Ventricular End-Systolic Elastance in Infants and Children
Background: In certain conditions, there is a need for a specific and improved measure of cardiac performance. Routine methods for assessing left ventricular (LV) function are based on image-analysis or right heart monitoring which do not allow evaluation of ventriculo-arterial interaction. Chen et al presented a noninvasive method allowing measurement of end-systolic pressure–volume relation ...
متن کاملEffects of a Cardiac Glycoside in Combination with Propranolol on the Ischemic Heart of Conscious Dogs STEPHEN
The effects of coronary occlusion and of subsequent propranolol and ouabain administration were examined in 12 conscious dogs. Overall left ventricular (LV) function was assessed by measurement of LV pressure and dP/dt, and regional myocardial function was assessed by measurements of segment length (SL), velocity of SL shortening and regional myocardial "work," i.e., pressure-length loops in no...
متن کاملEffects of Short-term Renovascular Hypertension and Type 2 Diabetes on Cardiac Functions in Rats
Background: The cardiac effects simultaneously occurring during experimental hypertension and diabetes have rarely been investigated. This study aimed at examining the effects of short-term renovascular hypertension and type 2 diabetes on cardiac functions. Methods: Five groups (7 each) of male Sprague-Dawley rats, including a control group, a diabetes (induced by Streptozocin and Nicotinamide)...
متن کاملAdmittance‐based pressure–volume loops versus gold standard cardiac magnetic resonance imaging in a porcine model of myocardial infarction
Abstract A novel admittance-based pressure-volume system (AS) has recently been developed and introduced. Thus far, the new technique has been validated predominantly in small animals. In large animals it has only been compared to three-dimensional echocardiography (3DE) where the AS showed to overestimate left ventricular (LV) volumes. To fully determine the accuracy of this device, we compare...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physiological measurement
دوره 32 6 شماره
صفحات -
تاریخ انتشار 2011