The Camino intracranial pressure sensor: is it optimal technology? An internal audit with a review of current intracranial pressure monitoring technologies.

نویسندگان

  • I Piper
  • A Barnes
  • D Smith
  • L Dunn
چکیده

OBJECTIVE To audit the reliability of the Camino intracranial pressure (ICP) sensor (Camino Laboratories, San Diego, CA) in our clinical practice as part of a continuing quality assurance program, and to assess its relative usefulness as compared with currently available ICP monitoring technologies that we reviewed. DESIGN Prospective audit of ICP device reliability and function in 50 patients with head injuries. METHODS Zero drift was recorded immediately after the ICP device was removed from the patient. Dynamic frequency response bench testing of each functioning catheter from 0 to 30 Hz and static calibration testing from 0 to 100 mmHg during environmental temperature variation from 22 to 40 degrees C were carried out. RESULTS Zero drift (range, -13 to 22 mmHg; median, -1 mmHg) was recorded immediately after the devices were removed from patients. Seventeen (50%) of the devices tested for zero drift had absolute drifts of at least 3 mmHg. There was no correlation between recorded zero drift and duration of monitoring (r = 0.154, P = 0.207). Five sensors (10% of those tested) failed during patient monitoring and were replaced. Static and dynamic calibration tests of the functioning sensors were within the manufacturer's specifications. However, the sensitivity of the devices to environmental temperature remains a problem. CONCLUSION The Camino ICP sensor remains one of the most popular ICP monitoring devices for use in patients with traumatic brain injuries. However, our recent in-house assessment demonstrated the robustness of the device to be less than adequate during routine practice. In this study, more than 50% exhibited zero drift greater than 3 mmHg, which is unacceptable in a catheter tip ICP monitoring device in which zero drift and calibration cannot be checked in vivo. A review of the literature revealed that other available ICP monitoring devices may prove to be more reliable and thus more appropriate for routine clinical measurement of ICP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Colombian-based survey on ventriculostomy and intracranial pressure monitor placement practices

Objective: Monitoring of intracranial pressure (ICP) is a routine procedure in the neurosurgery field. Although the routine practice of monitoring ICP has decreased in recent years, the practice patterns have not been studied in Colombia. This study was designed to evaluate the current practice forventriculostomy and ICP monitoring by neurosurgeons in Colombia. Methods...

متن کامل

Intracranial pressure: why we monitor it, how to monitor it, what to do with the number and what's the future?

PURPOSE OF REVIEW The review touches upon the current physiopathological concepts relating to the field of intracranial pressure (ICP) monitoring and offers an up-to-date overview of the ICP monitoring technologies and of the signal-analysis techniques relevant to clinical practice. RECENT FINDINGS Improved ICP probes, antibiotic-impregnated ventricular catheters and multimodality, computeriz...

متن کامل

Effect of cervical collars on intracranial pressure in patients with head neurotrauma

Trauma patients are at high risk of cervical and associated injuries. The standard protocol includes immobilization of the cervical spine in a polytrauma as it will help to prevent spinal injuries in the prehospital settings. Hard cervical collar (or alternatives) is routinely used until the cervical spine clearance is obtained . In patients with traumatic brain injury avoiding any kind of mane...

متن کامل

Design of High Sensitivity and Linearity Microelectromechanical Systems Capacitive Tire Pressure Sensor using Stepped Membrane

This paper is focused on a novel design of stepped diaphragm for MEMS capacitive pressure sensor used in tire pressure monitoring system. The structure of sensor diaphragm plays a key role for determining the sensitivity of the sensor and the non-linearity of the output.First the structures of two capacitive pressure sensors with clamped square flatdiaphragms, with different thicknesses are inv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Neurosurgery

دوره 49 5  شماره 

صفحات  -

تاریخ انتشار 2001