The twister fiber: a comparative study of tissue interaction between this novel fiber and the side-firing fiber using the 980 nm laser in bovine kidneys.
نویسندگان
چکیده
Twister fiber has been recently introduced to convey the 980 nm laser. It is an end-firing fiber with terminal angulation. Theoretically, this fiber has many advantages over the standard side-firing fiber. Tissue characterization for such fiber has not been performed until now. It is important to carry out such a task to better understand the performance of this type of laser using this new fiber. Ablation capacity, fiber degradation, and maximum coagulation depth were tested for both the side-firing and the Twister fibers using a 980 nm diode laser system with a maximum output of 300 watts (Ceralas 300 system). The fibers have been tested on bovine kidneys. Laser powers used were 50, 100, 150, and 200 watts. The application time was 3 minutes for each experiment. Each experiment was repeated six times. Ablation rate was directly proportional to laser power reaching 2.4 ± 0.24 g/minute for the side-firing fiber and 1.83 ± 0.23 g/minute for the Twister fiber when the 200 watts power was reached. There was no statistical significant difference between the two fibers except at the 200 watts power. The side-firing fiber seems to resist degradation better at high power. The maximum coagulation depth was equivalent and did not significantly increase with power increase beyond the 100 watts. At 50 watts, the coagulation depth was significantly lower in the side-firing fiber. Both fibers produced significantly smaller coagulation at the 50 watts power setting compared with higher powers. In conclusion, both fibers performed well with regard to the ablation rate and produced a reasonable coagulation zone beyond the ablation area. The side-firing fiber seems to resist degradation more than the Twister fiber.
منابع مشابه
Observation of Raman Gain in Reduced Length of Bismuth Erbium Doped Fiber
Raman amplification of a 49 cm Bismuth oxide (Bi2O3) as a nonlinear gainmedium based erbium doped fiber amplifier (EDFA) is reported in new and compactdesign in near infrared spectral regions. The bismuth glass host provides theopportunity to be doped heavily with erbium ions to allow a compact optical gain fiberamplifier design by using reduced fiber length and the 1480...
متن کاملشبیه سازی عددی و تحلیلی پرتابه های فرسایشی سرعت بالا در اهداف بتنی مسلح به الیاف فولادی
In this paper, modeling of high speed projectiles with different nose shapes, penetrating into steel fiber reinforced concrete is investigated. This is a novel study because it considers the length to diameter ratio of steel fiber as well as projectile length to diameter ratio and volume fraction of fiber used in concrete matrix on the impact resistance of steel fiber reinforced concrete fibers...
متن کاملPerformance assessment of novel side firing safe tips for endodontic applications.
During root canal or periodontal treatment, directing laser energy onto the walls of the root canal is essential for effective disinfection. This study assessed the performance of four different fiber modifications that have increased lateral emission, including three designs with safe tips to reduce irradiation directed toward the root apex. Free-running pulsed infrared lasers (Nd:YAG, Er:YAG,...
متن کاملHistologic evaluation of laser lipolysis: pulsed 1064-nm Nd:YAG laser versus cw 980-nm diode laser.
BACKGROUND The use of the laser as an auxiliary tool has refined the traditional technique for lipoplasty. During laser lipolysis, the interaction between the laser and the fat produced direct cellular destruction before the suction, reduced bleeding, and promoted skin tightening. OBJECTIVE This study sought to perform a comparative histologic evaluation of laser lipolysis with the pulsed 106...
متن کاملInterstitial Laser Photocoagulation Using 980 nm Diode Laser in Benign Thyroid Nodule: A Feasibility Study
The aim of this study was to investigate the feasibility of using 980 nm diode laser for interstitial laser photocoagulation (ILP) before clinical application in benign thyroid nodule treatment. The bovine livers were cut into blocks to irradiate with 980 nm laser through the lumen of a 20-gauge spinal needle using a fiber optic guide. Laser irradiation was performed with the output power of 2 ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of endourology
دوره 24 11 شماره
صفحات -
تاریخ انتشار 2010