Mechanisms mediating visual detection in static perimetry.

نویسندگان

  • R S Harwerth
  • E L Smith
  • L DeSantis
چکیده

PURPOSE The usual stimuli in static perimetry are white-light luminance increments. However, the specific visual detection mechanisms involved in perimetry are unknown because all classes of neural mechanisms are sensitive to spectrally broadband stimuli. The objective of this study was to determine the relative sensitivities of nonopponent and opponent detecting mechanisms under standard perimetry test conditions. METHODS Using trained rhesus monkey subjects, the relative sensitivities of the vision mechanisms for the detection of perimetry test stimuli were determined through psychophysical measurements of spectral sensitivity at each of the test field locations of the C24-2 threshold program on the Humphrey Field Analyzer (Allergan Humphrey, San Leandro, CA). The spectral sensitivity functions were analyzed by a three-channel model that incorporated independent short-wavelength-sensitive, nonopponent (luminance), and opponent (chromatic) spectral sensitivity mechanisms. RESULTS The visual detection mechanisms for perimetry thresholds varied as a function of the size and wavelength of the test field. With the perimeter's standard stimulus (Goldmann Size III) and bowl illumination (31.5 asb), the presence of a short-wavelength-sensitive mechanism was clearly evident at all field locations, but its relative sensitivity systematically declined with eccentricity. Under these conditions, the sensitivities of the opponent and nonopponent mechanisms were approximately equal at most field locations. With a larger stimulus (Goldmann Size V), however, the contribution of the opponent spectral sensitivity mechanism was more apparent over most of the central field and the alterations of sensitivity with eccentricity were less pronounced. In contrast, a small test field (Goldmann Size II) appeared to bias detection toward nonopponent mechanisms. CONCLUSION The results of these investigations indicate that detection thresholds during perimetry can be effectively biased toward different photopic, visual processing channels through the appropriate selection of size and wavelength of the test stimulus.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mechanisms isolated by frequency-doubling technology perimetry.

PURPOSE The frequency-doubling (FD) phenomenon describes the increase in apparent spatial frequency occurring when low-spatial-frequency sine wave gratings undergo rapid counterphase flicker. It is unclear whether the visual mechanisms isolated when pattern appearance is used as a threshold criterion are the same as when a simple detection criterion (as in FD perimetry) is used. It is also uncl...

متن کامل

Comparison of visual evoked potentials, automated perimetry and frequency-doubling perimetry in early detection of glaucomatous visual field loss.

The present study compares frequency-doubling perimetry (FDP), automated perimetry (AP) and visual evoked potentials (VEP) for their ability to diagnose early glaucoma. In present study 224 patients of Clinic for Eye Diseases, Clinical Hospital "Sestre Milosrdnice" that had diagnosis of open angle glaucoma and glaucomatous visual field loss proven by automated static perimetry on only one eye w...

متن کامل

Comparison of Octopus Semi-Automated Kinetic Perimetry and Humphrey Peripheral Static Perimetry in Neuro-Ophthalmic Cases

Aim. To compare semikinetic perimetry (SKP) on Octopus 900 perimetry to a peripheral static programme with Humphrey automated perimetry. Methods. Prospective cross-section study comparing Humphrey full field (FF) 120 two zone programme to a screening protocol for SKP on Octopus perimetry. Results were independently graded for presence/absence of field defect plus type and location of defect. Re...

متن کامل

Assessment of central retinal function in patients with advanced retinitis pigmentosa.

PURPOSE To assess central retinal function in patients with advanced retinitis pigmentosa (RP) using the multifocal (mf)ERG and static perimetry. METHODS Patients with RP; a nonrecordable, full-field (ff)ERG; and visual acuity (VA) of </= 1.0 logMAR were included. All patients underwent mfERG testing (103 hexagons, and 2.67 and 5.33 cd . s . m(-2) flash intensities) and static perimetry (103 ...

متن کامل

Perceptual relevance of abnormal visual field representations: static visual field perimetry in human albinism.

BACKGROUND In human albinism the plasticity of the visual system is challenged, as part of the temporal retina projects abnormally to the contralateral hemisphere. AIM To investigate whether the sensitivity of the abnormally projecting temporal retina is preserved. METHODS Light spot detection sensitivities were assessed in the central 20 degrees of the visual field in 15 patients with albi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 34 10  شماره 

صفحات  -

تاریخ انتشار 1993