Implementation of GOIA-Wurst pulse in a SPECIAL localization sequence at 7T
نویسندگان
چکیده
Introduction In H MR spectroscopy the SPin ECho, full Intensity Acquired Localized (SPECIAL) acquisition sequence combines the advantages of ultra-short echo times (TE) with full sensitivity obtained by Spin Echo (SE) based sequences [1,2]. In particular, J-coupled multiplets and metabolites with short T2 relaxation times benefit from an improved SNR at the short TEs, which are in the order of milliseconds. Increased sensitivity can also be obtained at higher B0 fields, which also provide enhanced spectral resolution. As 7T is currently one of the highest fields available for humans, it makes sense to implement a sequence as SPECIAL on 7T MR systems. However, higher magnetic fields cause RF inhomogeneities and increased chemical shift artefacts in slice selective localization sequences. This can be overcome by applying adiabatic slice selective pulses with large RF bandwidths, though at the cost of an increase in minimal TE. The aim of this study was to replace the Mao refocusing pulse in SPECIAL with adiabatic pulses, to reduce chemical shift artefact and demands on high B1 amplitudes. To limit the penalty of increased TE, we implemented two GOIA pulses with WURST-16 modulations of the RF field and WURST-4 gradient modulations [3]. These GOIA-WURST(16,4) pulses provide a good excitation uniformity, a very wide BW of 20kHz, while pulse duration (3.56ms) and RF power (0.817kHz) are still comfortably within the limits of most headcoils at ultra-high field strengths. By implementing the two GOIA-W(16,4) pulses, TE increases from 6 to 12.7 ms. Modulation of coupled spin systems is decelerated due to spin locking during the adiabatic passage. To test the SPECIAL-GOIA combination we performed phantom measurements with both Mao and GOIA-W(16,4) refocusing pulses. Furthermore, we obtained in vivo brain spectra of a healthy volunteer. Method The SPECIAL sequence is a combination of a one-dimensional image-selected in vivo spectroscopy (ISIS) sequence and a slice selective SE sequence (Fig. 1). To obtain full localization three orthogonal slice selections were needed: 1. The 180 ̊ adiabatic inversion pulse of the ISIS-block was executed in alternate scans, while switching the phase of the receiver at the same time. 2. The use of an asymmetric slice-selective 90° excitation pulse allows ultra-short TE. 3. For 180° refocusing the SPECIAL sequence uses a Mao pulse with a BW of 1.8 kHz, a duration of 3.2 ms and a max RF power 1.7 kHz. In this study we replaced the Mao pulse with two adiabatic GOIA-W(16.4) pulses to achieve 180 ̊ refocusing. Each GOIA-W(16,4) pulse has a maximum RF power of 0.817 kHz, a BW of 20 kHz and a pulse duration of 3.56 ms. To suppress the water signal VAPOR and an additional Gaussian WS pulse were implemented. Outer volume suppression reduced contaminating lipid signals. All measurements were performed on a 7T Magnetom whole body MR system (Siemens Medical Solutions, Erlangen, Germany) operating at 297.18 MHz for H. For measurements in a large spherical brain phantom a custom-built 8-channel Tx/Rx microstrip coil with meanders [4] was used. The phantom contains the following metabolites: 12.5 mM NAA, 3 mM ChoCl, 10 mM Cr, 7.5 mM myoinositol, 5mM LiLac, 12.5 mM Glu, 50 mM K2PO4 and 56 mM NaOH. Both phantom measurements, with Mao and GOIA-W(16,4) refocusing pulses, were executed with the same parameters: VOI = 20×20×20 mm, spectral width = 4 kHz, 32 averages, vector size = 2048, TE = 5000ms and a total acquisition time of 2:41 min. Only the TEs differed, 6 ms for Mao and 12.7 ms for GOIA-W(16,4), respectively. The in vivo measurements were performed with a 7.0T TX/RX 32ch Head Coil (Nova Medical, Inc., Wilmington, MA, USA). Only signal contributing channels close to the VOI were selected to obtain an optimal signal. The VOI was positioned in grey matter of the parietal lobe of a female volunteer. The measurement parameters were: VOI = 15×15×15 mm, spectral width = 4 kHz, 48 averages, vector size = 2048, TE = 4000ms, TE = 6 ms for MAO and TE = 12.7 ms for GOIA-W(16,4). The total acquisition time was 3:13 min. Results and Discussion MR spectra obtained from the phantom with Mao and GOIA-W(16,4) are displayed in Fig 2, in a range of 1.8 – 3.5 ppm. Both spectra show very similar metabolic signal profiles, only very small differences are visible. The glutamate and NAA multiplets at 2.3, 2.5 and 2.7 ppm of the GOIA-spectrum show slightly lower intensities because of longer TE. The in vivo H MR spectra show similar results (Fig. 3). The NAA multiplets around 2.5 and 2.7 ppm again show a different spectral pattern due to the prolonged J-evolution at the longer TE. Conclusion We demonstrated that the SPECIAL acquisition sequence with the implemented GOIAW(16,4) pulses shows almost the same spectral patterns as the original sequence with Mao refocusing pulse. Because of the longer TE, some coupled spin systems, such as those of glutamate and NAA, show slight differences in multiplet-lineshape due to J-evolution. Only minor modifications in spectral shape for specific metabolites were observed. This sequence can be used as a proper alternative to obtain short TE MR spectra of the human brain with the benefit of reduced chemical shift artefact and less sensitivity to RF field inhomogeneities, which is particularly important at higher magnetic field. References [1] V.Mlynárik et al., Magn.Reson.Med 56: 965-970 (2006). [2] R.Mekle et al., Magn.Reson.Med 61: 1279-1285 (2009). [3] O.C.Andronesi et al., J.Magn.Res 203: 283-293 (2010). [4] S.Orzada et al., ISMRM 2009, Abstract 3010. Acknowledgements Funded by FAST Marie Curie Research and Training Network (MRTN-CT-2006-035801)
منابع مشابه
Gradient offset independent adiabatic pulses for high-field MR spectroscopy on clinical scanners
Adiabatic pulses are necessary to mitigate chemical shift artifact (CSA) and rf inhomogeneity at high-field MRS, but often they need longer durations (≥ 5 ms) and higher rf strengths (> 1 kHz) that limits their application in-vivo. Gradient offset independent adiabatic (GOIA) pulses have been proposed [1] as an elegant solution to reduce these requirements while effectively increasing the excit...
متن کاملCompensation of offresonance magnetization transfer artifact in SPECIAL at 7T
Introduction: The increase in spectral separation and signal-to-noise ratio at ultra-high field (7T and higher) strength enables the detection of a large number of low concentrated or coupled spin systems aside from the big landmark peaks NAA, creatine and choline. However, their detection is complicated by relatively short T2 relaxation times at ultra-high field strength (7T). The large spectr...
متن کاملIn vivo 31P-MRS at 7T by single voxel E-ISIS with GOIA selection pulses
The GOIA-HS(8,4) pulses used for ISIS localisation offered excellent slice profiles with high bandwidth (20-40kHz) similar to FOCI but at lower B1 (Fig.2) or shorter pulses (~3 ms) even in 5 cm distance to the surface coil. Large selective gradients (25mT/m) reduced the CSDE to ±1.4mm for the most important metabolites (PME to γ-ATP) independent of voxel size. Contamination tests with TR~1.2T1 ...
متن کاملSPECIAL-COSY at 7T
Introduction Metabolites of particular interest are neurotransmitters and their precursors such as glutamine (Gln), glutamate (Glu), N-acetyl-aspartyl-glutamate (NAAG) and gamma amino butyric acid (GABA), as well as antioxidants such as glutathione (GSH) and ascorbic acid (Asc / vitamin C), whose important roles in the pathophysiology of neurological and psychiatric disorders is still not fully...
متن کاملSPECIAL-j-resolved spectroscopy at 7T
Introduction In-vivo proton spectroscopy is a valuable tool that provides additional knowledge about basic metabolic processes for example in the human brain or important diagnostic in formation for various diseases. Unambiguous detection of coupled spin systems like Glutamate, Glutamine or GABA are quite challenging and hard to achieve with regular one dimensional single voxel spectroscopy. Mo...