Non-equispaced Fourier Transform Vs. Polynomial-Based Metal Artifact Reduction in Computed Tomography

نویسندگان

  • Bärbel Kratz
  • Tobias Knopp
  • Jan Müller
  • May Oehler
  • Thorsten M. Buzug
چکیده

We propose a method, which treats metal artifact reduction in CT by sinogram restoration as a problem of scattered data interpolation. Corrupted sinogram entries are discarded and replaced with artificially generated values. The presented interpolation algorithm is based on the 2D non-equispaced fast Fourier transform (NFFT). Results are compared to two common polynomial interpolation schemes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Metal Artifact Reduction software in Computed Tomography

Introduction: The image quality of computed tomography (CT) can be seriously lowered by metal implants of patients. These implants are known to exert a significant impact on diagnostic accuracy due to artifacts. The current study aimed to assess the usefulness of Metal Artifact Reduction (MAR) software in the reduction of metal artifacts, in comparison to iterative rec...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Metal Artifact Reduction of Dental Fillings in Head and Neck CT Images

Introduction: The issue of metal artifact and its reduction is as old as the clinical use of computed tomography itself. When metal objects such as dental fillings, hip prostheses or surgical clips are present in the computed tomography (CT) field of view (FOV), make severe artifacts that reduce the image quality and accuracy of CT numbers. They can lead to unreliable ...

متن کامل

Motion Artifact Compensation in CT

A new method for compensating motion artifacts in computerized tomography is presented. The algorithm operates on the raw data, that is, on the measured Radon transform. An edge detection is performed on the Radon transform image. Two curves are obtained from these edges, which are tted by a polynomial. The pointwise diierences between the edges of the Radon transform image and the tted curves ...

متن کامل

Non-Equispaced Fast Fourier Transforms in Turbulence Simulation

NON-EQUISPACED FAST FOURIER TRANSFORMS IN TURBULENCE SIMULATION SEPTEMBER 2017 ADITYA MOHAN KULKARNI, B. E., UNIVERSITY OF PUNE M.S.M.E. UNIVERSITY OF MASSACHUSETTS AMHERST Directed by: Prof. Stephen de Bruyn Kops Fourier pseudo-spectral method is one of the approaches used to compute the derivative of a discrete data in Computational Fluid Dynamics. The Fourier transform of the data sampled on...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008