Irradiation treatment of laryngeal cancer in a patient with an implantable cardioverter-defibrillator (ICD).

نویسندگان

  • Susanna Sepe
  • Pamela Schaffer
  • Klaus Krimmel
  • Moshe Schaffer
چکیده

BACKGROUND Due to an aging population the incidence of both cardiac and tumor-related illnesses is increasing. A problem may arise if radiotherapy is necessary in close anatomic proximity to an implantable cardioverter-defibrillator (ICD). These highly precise devices may respond to ionizing radiation with a loss of function or uncontrolled stimulation, with both effects being potentially life threatening. Available guidelines recommend the dose maximum to a pacemaker to be cumulative below 2 Gy. For most patients undergoing radiation therapy of the neck or of the chest this limit is exceeded, thus making a removal of the device and an implantation of an external ICD necessary. CASE REPORT A patient with severe cardiac problems underwent an implantation of an ICD. However, a recurrence of a laryngeal cancer was diagnosed. The irradiation dose after resection was 60 Gy to the tumor region and 50 Gy to the lymph nodes. Irradiation peakload to the ICD was calculated to be 2.5 Gy. This dose was verified with thermoluminescence measurements. The ICD was externally deactivated during the sessions of irradiation. Device checks demonstrated no malfunction. CONCLUSION Even though the dose limits of the ICD of 2 Gy were exceeded, the device demonstrated a regular function during and after radiotherapy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

The effect of education based on Orem’s self-care model on emotional reactions in patients with Implantable Cardioverter Defibrillator (ICD)

Abstract Aim. The purpose of this study was to examine the effect of education based on Orem’s self-care model on emotional reactions in people with Implantable Cardioverter Defibrillator (ICD). Background. ICD shock is unpredictable and associated with physical pain. After receiving shock, some patients find serious psychological problems such as anxiety, depression and stress. According to Or...

متن کامل

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

زندگی با دفیبریلاتور قابل کاشت: یک مطالعه پدیده‌شناسی

  Background & Aim: Implantable Cardioverter Defibrillator is the most effective treatment for cardiac dysrhythmias. Having such life-saving device is the unique experience with important changes in the patient’ life. Understanding of these experiences can lead to success in treatment and follow- up.This study aimed to understand the experiences of patients with Implantable Cardioverter Defibri...

متن کامل

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Onkologie

دوره 30 7  شماره 

صفحات  -

تاریخ انتشار 2007