SU-F-BRCD-01: A Novel Dual Source Array Tetrahedron Beam Computed Tomography (TBCT) System for Image Guided Radiotherapy.
نویسندگان
چکیده
PURPOSE To design and test the feasibility of a novel dual source array, dual detector array TBCT system which is capable of both volumetric CT imaging as well as real-time stereoscopic x-ray imaging for image guided radiotherapy (IGRT). METHODS Besides producing improved image quality, the geometry of TBCT is also more compact and flexible. It is possible to mount two x-ray source arrays and two detector arrays on a LINAC gantry. Each pair of source/detector arrays generates real-time fluoroscopy images at four different view angles, which can be used in real-time target/marker tracking. FDK and iterative CT image reconstruction algorithms were developed for this new geometry. Stereoscopic imaging was simulated using CT images of prostate patients with implanted radiopaque markers. RESULTS Although the cone angles to the central slice of the reconstructed image are nonzero due to the shifting of the detector arrays, reconstructed patient CT images are visually identical to the original fan beam images. Anatomical structures and implanted radiopaque markers are visible in at least two of the radiography images. The 3-D spatial coordinates of the implanted markers can be determined from the stereoscopic images. CONCLUSIONS TBCT with dual source and dual detector arrays can produce high quality CT images as well as real-time stereoscopic imaging for target tracking. High quality online CT images and stereoscopic imaging in MV beam-eye-view direction can be very useful for advanced treatment techniques. Tiezhi Zhang and Joshua Kim have financial interest in TetraImaging Inc.
منابع مشابه
Microsoft Word - support_XXacmp_added.DOC
Introduction: Cone beam computer tomography (CBCT) suffers inferior image quality due to scatter and other problems. We are developing a novel tetrahedron beam computed tomography (TBCT) imaging system which consists of a linear scan x-ray source and a linear x-ray detector array. TBCT system avoids the inherent problems of CBCT, thereby can significantly improve the quality of online images in...
متن کاملEvaluation of Algebraic Iterative Image Reconstruction Methods for Tetrahedron Beam Computed Tomography Systems
Tetrahedron beam computed tomography (TBCT) performs volumetric imaging using a stack of fan beams generated by a multiple pixel X-ray source. While the TBCT system was designed to overcome the scatter and detector issues faced by cone beam computed tomography (CBCT), it still suffers the same large cone angle artifacts as CBCT due to the use of approximate reconstruction algorithms. It has bee...
متن کاملThe Impact of Residual Geometric Inaccuracies on Normal Organ Doses in Image Guided-Radiation Therapy of Prostate Cancer Using On-Board Kilovoltage Cone-Beam Computed Tomography
Introduction: The aim of this retrospective study was to evaluate the variations in delivered dose to the bladder, rectum, and femoral heads of prostate cancer patients during a course of treatment by image-guided radiation therapy (IGRT). Materials and Methods: Overall, 15 patients with prostate cancer were selected and. Each week, for each patient five consecutive cone beam computed tomograph...
متن کاملComparative Study between Electronic Portal Imaging Device (EPID) and Cone Beam Computed Tomography (CBCT) for Radiation Treatment Verifications
Introduction: Electronic Portal Imaging Device (EPID) and Cone Beam Computed Tomography (CBCT) are the preferred tools of Image Guided Radiotherapy (IGRT) and Dose Guided Radiotherapy (DGRT) which have been used for Radiotherapy treatment verifications. As a result, the number of publications dealing with these two tools for radiation treatment verification has increased consi...
متن کاملMethods to evaluate the performance of kilovoltage cone-beam computed tomography in the three-dimensional reconstruction space
Background: Cone-beam computed tomography (CBCT) scanners for image-guided radiotherapy are in clinical use today, but there has been no consensus on uniform acceptance to verify the CBCT image quality yet. The present work proposed new methods to fully evaluate the performance of CBCT in its three-dimensional (3D) reconstruction space. Materials and Methods: Compared to the traditional methods...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medical physics
دوره 39 6Part20 شماره
صفحات -
تاریخ انتشار 2012