Comparison of 3 He and 129 Xe MRI for evaluation of lung microstructure and ventilation at 1.5T.

نویسندگان

  • Neil J Stewart
  • Ho-Fung Chan
  • Paul J C Hughes
  • Felix C Horn
  • Graham Norquay
  • Madhwesha Rao
  • Denise P Yates
  • Rob H Ireland
  • Matthew Q Hatton
  • Bilal A Tahir
  • Paul Ford
  • Andrew J Swift
  • Rod Lawson
  • Helen Marshall
  • Guilhem J Collier
  • Jim M Wild
چکیده

BACKGROUND To support translational lung MRI research with hyperpolarized 129 Xe gas, comprehensive evaluation of derived quantitative lung function measures against established measures from 3 He MRI is required. Few comparative studies have been performed to date, only at 3T, and multisession repeatability of 129 Xe functional metrics have not been reported. PURPOSE/HYPOTHESIS To compare hyperpolarized 129 Xe and 3 He MRI-derived quantitative metrics of lung ventilation and microstructure, and their repeatability, at 1.5T. STUDY TYPE Retrospective. POPULATION Fourteen healthy nonsmokers (HN), five exsmokers (ES), five patients with chronic obstructive pulmonary disease (COPD), and 16 patients with nonsmall-cell lung cancer (NSCLC). FIELD STRENGTH/SEQUENCE 1.5T. NSCLC, COPD patients and selected HN subjects underwent 3D balanced steady-state free-precession lung ventilation MRI using both 3 He and 129 Xe. Selected HN, all ES, and COPD patients underwent 2D multislice spoiled gradient-echo diffusion-weighted lung MRI using both hyperpolarized gas nuclei. ASSESSMENT Ventilated volume percentages (VV%) and mean apparent diffusion coefficients (ADC) were derived from imaging. COPD patients performed the whole MR protocol in four separate scan sessions to assess repeatability. Same-day pulmonary function tests were performed. STATISTICAL TESTS Intermetric correlations: Spearman's coefficient. Intergroup/internuclei differences: analysis of variance / Wilcoxon's signed rank. Repeatability: coefficient of variation (CV), intraclass correlation (ICC) coefficient. RESULTS A significant positive correlation between 3 He and 129 Xe VV% was observed (r = 0.860, P < 0.001). VV% was larger for 3 He than 129 Xe (P = 0.001); average bias, 8.79%. A strong correlation between mean 3 He and 129 Xe ADC was obtained (r = 0.922, P < 0.001). MR parameters exhibited good correlations with pulmonary function tests. In COPD patients, mean CV of 3 He and 129 Xe VV% was 4.08% and 13.01%, respectively, with ICC coefficients of 0.541 (P = 0.061) and 0.458 (P = 0.095). Mean 3 He and 129 Xe ADC values were highly repeatable (mean CV: 2.98%, 2.77%, respectively; ICC: 0.995, P < 0.001; 0.936, P < 0.001). DATA CONCLUSION: 129 Xe lung MRI provides near-equivalent information to 3 He for quantitative lung ventilation and microstructural MRI at 1.5T. LEVEL OF EVIDENCE 3 Technical Efficacy Stage 2 J. Magn. Reson. Imaging 2018.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

RF instrumentation for same‐breath triple nuclear lung MR imaging of 1H and hyperpolarized 3He and 129Xe at 1.5T

PURPOSE The hyperpolarized gases (3)He and (129)Xe have distinct properties and provide unique and complementary functional information from the lungs. A triple-nuclear, same-breath imaging examination of the lungs with (1)H, (3)He, and (129)Xe can therefore provide exclusive functional information from the gas images. In addition, the (1)H images provide complementary co-registered structural ...

متن کامل

Pulmonary ventilation visualized using hyperpolarized helium-3 and xenon-129 magnetic resonance imaging: differences in COPD and relationship to emphysema.

In subjects with chronic obstructive pulmonary disease (COPD), hyperpolarized xenon-129 ((129)Xe) magnetic resonance imaging (MRI) reveals significantly greater ventilation defects than hyperpolarized helium-3 ((3)He) MRI. The physiological and/or morphological determinants of ventilation defects and the differences observed between hyperpolarized (3)He and (129)Xe MRI are not yet understood. H...

متن کامل

Hyperpolarized Gas MRI of the Lungs

The hyperpolarized gases 3 He and 129 Xe are prepared with a magnetization that is 100,000-fold larger than what could be attained by simple thermal equilibrium. This extraordinary magnetization overcomes the low density of these gases and permits them to be imaged with high spatial and temporal resolution. The principles of gas hyperpolarization have been reviewed in a very accessible manner b...

متن کامل

Hyperpolarized 3He and 129Xe magnetic resonance imaging apparent diffusion coefficients: physiological relevance in older never‐ and ex‐smokers

Noble gas pulmonary magnetic resonance imaging (MRI) is transitioning away from (3)He to (129)Xe gas, but the physiological/clinical relevance of (129)Xe apparent diffusion coefficient (ADC) parenchyma measurements is not well understood. Therefore, our objective was to generate (129)Xe MRI ADC for comparison with (3)He ADC and with well-established measurements of alveolar structure and functi...

متن کامل

Multiple breath washout of hyperpolarized 129Xe and 3He in human lungs with three‐dimensional balanced steady‐state free‐precession imaging

PURPOSE To compare quantitative fractional ventilation measurements from multiple breath washout imaging (MBW-I) using hyperpolarized 3 He with both spoiled gradient echo (SPGR) and balanced steady-state free precession (bSSFP) three-dimensional (3D) pulse sequences and to evaluate the feasibility of MBW-I with hyperpolarized 129 Xe. METHODS Seven healthy subjects were scanned using 3 He MBW-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره   شماره 

صفحات  -

تاریخ انتشار 2018