Partial Pressure Measurement

نویسنده

  • J. H. Leck
چکیده

The quadrupole mass spectrometer is now well established as the instrument used almost universally for partial pressure measurement. This spectrometer can be considered as a hot-cathode extractor ionisation gauge with the addition of an electrostatic mass filter between the ion source and the ion collector. This filter consists of a square array of circular rods approximately 6 mm diameter and between 100 to 150-mm long. Positive ions are injected parallel to the central axis towards the ion collector. A filtering action is achieved by applying combined radio frequency and dc potentials between opposite pairs of rods. The characteristics of the filter can be controlled by small changes in the relative values of the radio frequency and dc voltages and the mass range by changes in the frequency of the ac signal. Care must always be taken when operating this mass spectrometer in an analytical mode because of non-linearities caused by space charge and other effects which are important, particularly in the injection region between the ion source and filter. Also the filter is subject to loss of sensitivity over the long term, generally caused by contamination from hydrocarbon impurities in the vacuum system. This is not normally a problem in ultra-high vacuum operation. Although almost all filters have been designed to operate with relatively low voltages applied to the rods, alternative modes are being considered which require distinctly high voltages or lower frequencies. There are hopes that these will have advantages for general operation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of N2 partial pressure on the structural and mechanical properties of TaN films

TaN films with different N2 partial pressure were deposited on 304 stainless steel using the magnetron sputtering method. The effect of gas pressure on the mechanical property, morphology and phase structure of the films is investigated by X-ray diffraction (XRD), atomic force microscopy (AFM), microhardness testing, friction coefficient measurements, and wear mechanism study. The XRD results c...

متن کامل

Chapter 32 – The Physiology of the Avian Embryo

Ap effective pore area CAM chorioallantoic membrane CO cardiac output CO2 carbon dioxide dCO2 carbon dioxide diffusion coefficient dH2O water vapor diffusion coefficient dO2 oxygen diffusion coefficient DO2 oxygen diffusing capacity EP external pipping FcOX mean corpuscular oxygenation velocity GCO2 carbon dioxide conductance GH2O water vapor conductance GO2 oxygen conductance Hb hemoglobin Hct...

متن کامل

Effect of CO2 Partial Pressure on the Thermal Decomposition Kinetics of Zinc Carbonate Hydroxide (TECHNICAL NOTE)

In this work, the effect of carbon dioxide partial pressure on the calcination kinetics of high purity zinc carbonate hydroxide has been studied. Non-isothermal analysis has been performed on samples at different CO2 partial pressures by TGA and DTA. It has been found that the calcination behaviour of this material corresponds to the shrinking core model and the reaction mechanism is phase boun...

متن کامل

Spatially resolved optical measurements of water partial pressure and temperature in a PEM fuel cell under dynamic operating conditions

In situ non-intrusive measurements of water vapor partial pressure and temperature were performed simultaneously along two gas channels on he cathode side of a PEM fuel cell using tunable diode laser absorption spectroscopy. This measurement technique developed by us was utilized arlier to make measurements in a single bipolar plate channel of a prototype PEM fuel cell. The current study examin...

متن کامل

An interlaboratory study of blood-gas analysis: dependence of pO2 and pCO2 results on atmospheric pressure.

Blood-gas data from a large interlaboratory survey were analyzed to determine whether pO2 and pCO2 results are affected by the atmospheric pressure at the measuring location. A small but statistically significant dependence was found, averaging about 2.3% per 100 mmHg (1.7% per 10 kPa) for pO2 and 1.0% per 100 mmHg (0.75% per 10 kPa) for pCO2.

متن کامل

Reliability of transcutaneous measurement of oxygen and carbon dioxide partial pressure with a combined Po2-Pco2 electrochemical sensor in the fetus during labor.

A combined single electrochemical sensor designed to measure synchronously and transcutaneously oxygen partial pressure and carbon dioxide partial pressure (RADIOMETER prototype) was applied onto the scalp in 21 fetuses during labor. The values of tcPo2 respectively tcPco2 were compared with the values of fetal blood analysis (FBA) and blood from the umbilical artery (UA): Comparing the tcPco2 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999