Diagnosing dry eye with dynamic-area high-speed videokeratoscopy.

نویسندگان

  • David Alonso-Caneiro
  • Jason Turuwhenua
  • D Robert Iskander
  • Michael J Collins
چکیده

Dry eye syndrome is one of the most commonly reported eye health conditions. Dynamic-area high-speed videokeratoscopy (DA-HSV) represents a promising alternative to the most invasive clinical methods for the assessment of the tear film surface quality (TFSQ), particularly as Placido-disk videokeratoscopy is both relatively inexpensive and widely used for corneal topography assessment. Hence, improving this technique to diagnose dry eye is of clinical significance and the aim of this work. First, a novel ray-tracing model is proposed that simulates the formation of a Placido image. This model shows the relationship between tear film topography changes and the obtained Placido image and serves as a benchmark for the assessment of indicators of the ring's regularity. Further, a novel block-feature TFSQ indicator is proposed for detecting dry eye from a series of DA-HSV measurements. The results of the new indicator evaluated on data from a retrospective clinical study, which contains 22 normal and 12 dry eyes, have shown a substantial improvement of the proposed technique to discriminate dry eye from normal tear film subjects. The best discrimination was obtained under suppressed blinking conditions. In conclusion, this work highlights the potential of the DA-HSV as a clinical tool to diagnose dry eye syndrome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predicting dry eye using noninvasive techniques of tear film surface assessment.

PURPOSE To measure tear film surface quality in healthy and dry eye subjects using three noninvasive techniques of tear film quality assessment and to establish the ability of these noninvasive techniques to predict dry eye. METHODS Thirty-four subjects participated in the study and were classified as dry eye or normal, based on standard clinical assessments. Three noninvasive techniques were...

متن کامل

Tear film surface quality with rigid and soft contact lenses.

OBJECTIVES The aim of this study was to measure tear film surface quality (TFSQ) using dynamic high-speed videokeratoscopy during short-term (8 hrs) use of rigid and soft contact lenses. METHODS A group of 14 subjects wore 3 different types of contact lenses on 3 different nonconsecutive days (order randomized) in 1 eye only. The subjects were screened to exclude those with dry eye. The lense...

متن کامل

Interaction between topographic/tomographic parameters and dry eye disease in keratoconus patients.

PURPOSE To determine the interaction between corneal topographic and tomographic parameters and dry eye syndrome (DES) in keratoconus (KC) patients. METHODS Seventy-seven eyes of 49 patients with KC (age 34.4 ± 11.6 years) were enrolled in this study. In these 77 eyes we recorded surface regularity index (SRI), surface asymmetry index (SAI) and Klyce/Maeda KC index (KCI) using the Topographic...

متن کامل

Noninvasive in vivo assessment of soft contact lens type on tear film surface quality.

PURPOSE To evaluate the effect of soft contact lens type on the in vivo tear film surface quality (TFSQ) on daily disposable lenses and to establish whether two recently developed techniques for noninvasive measurement of TFSQ can distinguish between different contact lens types. METHODS Thirteen subjects wearing four different types of daily soft contact lenses participated in the study. Dyn...

متن کامل

Switched-Capacitor Dynamic Threshold PMOS (SC-DTPMOS) Transistor for High Speed Sub-threshold Applications

This work studies the effects of dynamic threshold design techniques on the speed and power of digital circuits. A new dynamic threshold transistor structure has been proposed to improve performances of digital circuits. The proposed switched-capacitor dynamic threshold PMOS (SC-DTPMOS) scheme employs a capacitor along with an NMOS switch in order to effectively reduce the threshold voltage of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 16 7  شماره 

صفحات  -

تاریخ انتشار 2011