Most Active File Measurement Validation in Hackystat

نویسندگان

  • Hongbing Kou
  • Xiangli Xu
چکیده

Hackystat, an automated metric collection and analysis tool, adopts the “Most Active File” measurement in five-minute time chunks to represent the developers’ effort. This measurement is validated internally in this report. The results show that big time chunk sizes are highly linear regressive with the standard time chunk size (1 minute). The percentage of missed effort to total effort is very low with five minutes chunk size. And the relative ranking with respect to the effort of the active files is only slightly changed. Keyword Hackystat, Most Active File Measurement, Linear Regression

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Understanding HPC Development through Automated Process and Product Measurement with Hackystat

The high performance computing (HPC) community is increasingly aware that traditional low-level, execution-time measures for assessing high-end computers, such as flops/second, are not adequate for understanding the actual productivity of such systems. In response, researchers and practitioners are exploring new measures and assessment procedures that take a more wholistic approach to high perf...

متن کامل

Continuous GQM: An automated measurement framework for the GQM paradigm

Measurement is an important aspect of Software Engineering as it is the foundation of predictable and controllable software project execution. Measurement is essential for assessing actual project progress, establishing baselines and validating the effects of improvement or controlling actions. The work performed in this thesis is based on Hackystat [1], a fully automated measurement framework ...

متن کامل

Accuracy of an Intraoral Digital System for File Length Measurement

Introdouction: Canal length measurement is essential for proper endodontic treatment. Any error or miscalculation in working length determination, particularly in curved canals, can result in complications during or after root canal therapy. Digital radiography has enabled accurate measurement of curved canal length. In this study, we evaluated the accuracy of calibration of a complementary m...

متن کامل

Development and Validation of Active Performance Indicators of Electrical Safety Using Bow-Tie and Bayesian Network Techniques Case Study: Oil and Gas Industries Construction Projects

Background: With the developing use of electricity in all aspects of human life, electricity accidents have also increased. One of the main components of the for the prevention policy, is the safety performance assessment of the organization's or industry's by using appropriate performance indicators with related operations.   Method: This study was a descriptive-analytical of 6 steps inc...

متن کامل

بررسی عملکرد کالیبراسیون نرم‌افزار سیستم دیجیتال CMOS در ارزیابی طول کارکرد کانال

Background and Aims: Estimating the canal length is essential for reaching to a proper endodontic treatment. Any error and miscalculation in estimation of the working length, especially in curved canals, can result in complication during and after root canal therapy. The introduction of digital radiography has enabled us to measure curved canal length. The purpose of this study was to evaluat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003