Optimized method for correct left-sided central venous catheter placement under electrocardiographic guidance.

نویسندگان

  • J Kremser
  • F Kleemann
  • K Reinhart
  • W Schummer
چکیده

BACKGROUND Central venous catheter (CVC) placement under ECG guidance in the left thoracocervical area can lead to catheter misplacement. The aim of this study was to identify the cause and quantify the magnitude of this error. METHODS CVCs were sited in either the left or right internal jugular (IJ), subclavian (SC), or innominate (brachiocephalic) vein using the Seldinger technique and a total of 227 insertions were studied. The position of the catheter tip was confirmed with two different intra-atrial ECG monitoring methods (Seldinger's wire vs 10% saline solution). Measurements were compared between the two methods and correlated to the different access sites. RESULTS All right-sided CVC had the line tip in the optimal position and both intra-atrial ECG recording by Seldinger's wire or 10% saline delivered correct results. For left-sided lines, however, the two methods gave significantly different results regarding the position of the line tip for each insertion site. When using the Seldinger wire as intravascular ECG lead, the results differed from the saline method by a mean of 21 mm for the IJ and 10 mm for the SC. CONCLUSIONS CVC placement under ECG guidance is a reliable method to site the line tip at the optimal position. However, when using a left-sided thoracocervical access point, the Seldinger wire-conducted ECG delivered a constant error. This could be adjusted for by advancing the CVC 20 mm in addition to the wire-based measurement of the insertion depth at the left IJ vein and 10 mm at the left SC vein.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal positioning of right-sided internal jugular venous catheters: Comparison of intra-atrial electrocardiography versus Peres' formula

Central venous catheters are routinely placed in patients undergoing major surgeries where expected volume and hemodynamic disturbances are likely consequences. The incorrect positioning may give false central venous pressure (CVP) readings leading to incorrect volume replacement and other serious complications. 50 American Society of Anaesthesiologists grade II-IV patients aged 18-60 years wer...

متن کامل

Unusual Placement of a Central Venous Catheter: Left Pericardiophrenic Vein

A 62-year-old man presented to the emergency department with hypotension and diarrhea secondary to Clostridium difficile infection. Due to poor peripheral access, a left internal jugular vein triple lumen central venous catheter (CVC) was inserted for fluid resuscitation. The CVC was placed under real-time ultrasound guidance, which revealed normal anatomy, with no resistance during placement. ...

متن کامل

Therapeutic embolization of an internal mammary artery damaged by placement of a central venous catheter.

We describe the embolization of a left internal mammary artery damaged by left internal jugular venous catheterization. Because potentially serious complications can occur with a blind approach for central venous catheterization, portable ultrasound machines should be used more often to ensure correct placement of the catheter.

متن کامل

The Placement of a Catheter in a Persistent Left Superior Vena Cava

A 75-year-old woman was admitted due to pyometra. A central venous catheter was inserted from the left internal jugular vein under ultrasound guidance to create a parenteral nutrition route (1). A post-procedural X-ray film led us to suspect that inadvertent intra-aortic catheterization had occurred (Picture a). Although a blood gas analysis obtained via the catheter indicated intravenous cathe...

متن کامل

Percutaneous Insertion of Hickman Central Venous Catheter: Jugular Approach

Traditionally, tunnelled central venous catheter insertions have been performed by surgeons. However, there is an increasing trend towards central catheters being placed by interventional radiologists under image guidance. The many advantages of inserting central catheters via the jugular approach under image guidance include reusable venous access, generally less waiting time compared with sur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 108 2  شماره 

صفحات  -