3D velocity quantification in the heart: improvements by 3D PC-SSFP.

نویسندگان

  • Marijn P Rolf
  • Mark B M Hofman
  • Joost P A Kuijer
  • Albert C van Rossum
  • Rob M Heethaar
چکیده

PURPOSE To test whether a 3D imaging sequence with phase contrast (PC) velocity encoding based on steady-state free precession (SSFP) improves 3D velocity quantification in the heart compared to the currently available gradient echo (GE) approach. MATERIALS AND METHODS The 3D PC-SSFP sequence with 1D velocity encoding was compared at the mitral valve in 12 healthy subjects with 3D PC-GE at 1.5T. Velocity measurements, velocity-to-noise-ratio efficiency (VNR(eff)), intra- and interobserver variability of area and velocity measurements, contrast-to-noise-ratio (CNR), and artifact sensitivity were evaluated in both long- and short-axis orientation. RESULTS Descending aorta mean and peak velocities correlated well (r(2) = 0.79 and 0.93) between 3D PC-SSFP and 3D PC-GE. At the mitral valve, mean velocity correlation was moderate (r(2) = 0.70 short axis, 0.56 long axis) and peak velocity showed good correlation (r(2) = 0.94 short axis, 0.81 long axis). In some cases VNR(eff) was higher, in others lesser, depending on slab orientation and cardiac phase. Intra- and interobserver variability was generally better for 3D PC-SSFP. CNR improved significantly, especially at end systole. Artifact levels did not increase. CONCLUSION 3D SSFP velocity quantification was successfully tested in the heart. Blood-myocardium contrast improved significantly, resulting in more reproducible velocity measurements for 3D PC-SSFP at 1.5T.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flow quantification in the heart chambers: 3D PC-SSFP compared with spoiled GE

Introduction: Flow quantification through the valves is of major importance in patients with valvular heart disease. Using a 3D MRI acquisition, the mitral valve can be imaged during the whole cardiac cycle, for direct quantification of flow through the valve. So far, 3D phase contrast (PC) for velocity quantification is only implemented in a spoiled Gradient Echo (GE) sequence. However, PC-GE ...

متن کامل

Mitral valve blood flow quantification by 7D phase contrast SSFP - a feasibility study

Purpose: to assess the feasibility of a new 7D PC-SSFP sequence for single acquisition mitral regurgitation volume quantification. Materials and Methods: The 7D PC-SSFP sequence implementation is based on a regular 3D balanced SSFP gradient scheme with velocity encoding. Accuracy of velocity quantification was confirmed using a flow-phantom. Mitral volume flow was measured in ten healthy subjec...

متن کامل

Comparison of 4D flow and 2D PC MRI blood flow quantification in children and young adults with congenital heart disease

Background Echocardiography (echo) is the primary imaging modality for assessment of aortic and pulmonary blood flow velocities. 2D phase contrast (PC) MRI provides better access to all segments of the aortic and pulmonary system and is considered the standard for evaluating blood flow. Both techniques are limited by velocity analysis in 2D planes and by single-direction velocity measurement wh...

متن کامل

Part I Flow Quantification of the Mitral Valve: Combining Phase Contrast with Ssfp

Multiecho phase-contrast steady-state free precession (PC-SSFP) is a recently introduced sequence for flow quantification. In this multiecho approach, a phase reference and a velocity-encoded readout were acquired at different echo times after a single excitation. In this study, the sequence is validated in vitro for stationary flow. Subsequently, the sequence was evaluated on cardiac output me...

متن کامل

Advanced Quantitative Flow and Wall Shear Stress Analysis at 3T: 2D Vs 3D Time-Resolved MR Velocity Mapping

Introduction: Time-resolved (CINE) phase contrast (PC) MRI permits the assessment of blood flow within entire 3D vascular structures [1, 2]. The resulting high-dimensional datasets (3 spatial dimensions, 3 velocity directions, and time) require new visualization and quantification methods to derive reliable clinical parameters. In this context, an advanced flow quantification tool was developed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 30 5  شماره 

صفحات  -

تاریخ انتشار 2009