Constant-time method for measuring inter-nuclear distances in static powders.

نویسندگان

  • Jae-Seung Lee
  • A K Khitrin
چکیده

We present a constant-time modification of a single-echo 2D technique for measuring the constants of spin-spin interaction between heteronuclei in static powder samples. Compared to the sequence with variable echo time, the new scheme provides higher resolution. Another important improvement is a possibility to eliminate the central peak from a natural-abundance matrix. The experimental results are presented for glycine-[13Calpha, 15N] and glycine-[13C', 15N].

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of virtual point for HPGe detector at various gamma rays energies by simulation and experimental methods

High Purity Germanium detectors (HPGe) are subdivisions of semiconductor detectors which are widely used in nuclear technology from space industry to nuclear medicine, due to their high resolution, low dead time, unlimited size and compatibility with a variety of environments. The( absolute and intrinsic) efficiency of the HPGe detector, which depends on the geometry of the source-detector syst...

متن کامل

Silastic Thickness Optimization in Uveal Melanoma Brachytherapy by Monte Carlo Method

Introduction In order to treat uveal Melanoma , first, radioactive seeds are laid on a silicone- made substance which is called Silastic after that they are inserted in the plaque, and finally, this plaque containing silicone-made substance is stitched to the sclera surface. The dose gradient within the tumor and healthy tissues can be varied due to changing the Silastic thickness between scler...

متن کامل

Measuring Access to Urban Health Services Using Geographical Information System (GIS): A Case Study of Health Service Management in Bandar Abbas, Iran

Background The current distribution of and access to health services along with the future health needs of the population have prompted wide application of Geographic Information Systems (GISs). During recent years, GIS has been used in public health management for planning and organization of healthcare services. This study investigates geographical accessibility of residential areas in Bandar...

متن کامل

Evaluation of ocular hydroxyapatite implant with Tc-99m MDP bone scan [Persian]

Static bone scan was performed in 46 patients for evaluation of ocular Hydroxyapatite Vascularization. Study Findings indicated that bone scan, with TC-99m MDP is an appropriate method for evaluation of Hydroxyapatite Vascularization and for estimating the time For peg insertion into the Hydroxyapatite implant. Our study showed proper Hydroxyapatite Vascularization when the ratio of activ...

متن کامل

Computing Atomic Density Changes of Material Composition in Operation of the Nuclear Reactor Core

The present work investigates an appropriate way to calculate the 1700 atomic density changes in the reactor operations. To automate this procedure, a computer program has been designed by C#. This program suggests a way to solve this problem which is based on the solution system of differential equations (Bitman) that it is designed according to Runge-Kutta Fehlberg method. The designed softwa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of magnetic resonance

دوره 186 2  شماره 

صفحات  -

تاریخ انتشار 2007