Monte Carlo simulation of DNA damage induction by x-rays and selected radioisotopes.

نویسندگان

  • Y Hsiao
  • R D Stewart
چکیده

To better assess the potential biological consequences of diagnostic x-rays and selected gamma-emitting radioisotopes used in brachytherapy, we used the PENELOPE Monte Carlo radiation transport code to estimate the spectrum of initial electrons produced by photons in single cells and in an irradiation geometry similar to those used in cell culture experiments. We then combined estimates of the initial spectrum of electrons from PENELOPE with DNA damage yields for monoenergetic electrons from the fast Monte Carlo damage simulation (MCDS). The predicted absolute yields (Gbp(-1) Gy(-1)) and RBE values for single-strand break (SSB) and double-strand break (DSB) induction by 220 kVp x-rays are within 1% of the results from detailed track-structure simulations (Friedland et al 1999 Radiat. Environ. Biophys. 38 39). The measured RBE for DSB induction reported by Kühne et al (2005 Radiat. Res. 164 669) for gamma-rays from (60)Co and for 29 kVp x-rays with a 50 microm Rh (mammography) filter are in excellent agreement (1.15 versus 1.16). DSB yields predicted by the MCDS also agree to within 7% with the absolute DSB yields reported by de Lara et al (2001 Radiat. Res. 155 440) and Botchway et al (1997 Radiat. Res. 148 317) for the irradiation of V79 cells by low energy (<2 keV) characteristic x-rays. The predicted RBE for DSB induction by gamma-rays from bare (169)Yb and (131)Cs to (60)Co are 1.06 and 1.14, respectively. Tabulated RBE values for the single-cell and monolayer cell culture geometries differ by at most 15%. The proposed methodology is computationally efficient and may also be useful for the prediction of damage yields for mixtures of other types of charged particles, such as those found in proton therapy, space applications or internal dosimetry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Monte Carlo Study on Dose Enhancement by Homogeneous and Inhomogeneous Distributions of Gold Nanoparticles in Radiotherapy with Low Energy X-rays

Background: To enhance the dose to tumor, the use of high atomic number elements has been proposed.Objective: The aim of this study is to investigate the effect of gold nanoparticle distribution on dose enhancement in tumor when the tumor is irradiated by typical monoenergetic X-ray beams by considering homogeneous and inhomogeneous distributions of gold nanoparticles (GNPs) in the tumor.Method...

متن کامل

Calculating of Dose Distribution in Tongue Brachytherapy by Different Radioisotopes using Monte Carlo Simulation and Comparing by Experimental Data

Introduction: Among different kinds of oral cavity cancers, the frequency of tongue cancer occurrence is more significant. Brachytherapy is the most common method to cure tongue cancers. Long sources are used in different techniques of tongue brachytherapy. The objective of this study is to asses the dose distribution around long sources, comparing different radioisotopes as brachytherapy sourc...

متن کامل

Evaluation of X-ray absorbed dose in thyroid during CXR imaging of the chest by Monte Carlo simulation (DOSXYZnrc)

Abstract:   Introduction: Chest radiography is one of the most common X-ray imaging procedures performed worldwide. During this process, in addition to the chest, other tissues, including the thyroid, are also exposed to radiation. Due to the fact that one of the most important risk factors for thyroid cancer is ionizing radiation, measuring the absorption of X- rays in the thyroid is of spec...

متن کامل

Modeling of Production Process of DNA Damage by Irradiation with Monochromatic X-rays around K-edge of Phosphorus

The mechanism of DNA strand break induction due to K-shell photoabsorption of DNA constituent phosphorus was studied by computer simulation. Photon induced Auger process in DNA solution was modeled and introduced to the Monte Carlo simulation code DBREAK, which allows the estimation of DNA strand break production on pBR322 plasmid DNA in aqueous solution. The simulation was carried out for the ...

متن کامل

A Monte Carlo Study on the Shielding Properties of a Novel Polyvinyl Alcohol (PVA)/WO3 Composite, Against Gamma Rays, Using the MCNPX Code

Background: In recent years, there has been an increased interest toward non-lead radiation shields consisting of small-sized filler particles doped into polymer matrices. In this paper, we study a new polyvinyl alcohol (PVA)/WO3 composite in the presence of high-energy gamma photons through simulation via the Monte Carlo N-Particle (MCNP) simulation code. Materia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 53 1  شماره 

صفحات  -

تاریخ انتشار 2008