Detection of hepatitis a virus by using a combined cell culture-molecular beacon assay.

نویسندگان

  • Hsiao-Yun Yeh
  • Yu-Chen Hwang
  • Marylynn V Yates
  • Ashok Mulchandani
  • Wilfred Chen
چکیده

Rapid and efficient methods for the detection and quantification of infectious viruses are required for public health risk assessment. Current methods to detect infectious viruses are based on mammalian cell culture and rely on the production of visible cytopathic effects (CPE). For hepatitis A virus (HAV), viral replication in cell culture has been reported to be nonlytic and relatively slow. It may take more than 1 week to reach the maximum production and subsequent visualization of CPE. A molecular beacon (MB), H1, specifically targeting a 20-bp 5' noncoding region of HAV, was designed and synthesized. MB H1 was introduced into fixed and permeabilized fetal rhesus monkey kidney (FRhK-4) cells infected with HAV strain HM-175. Upon hybridizing with the viral mRNA, fluorescent cells were visualized easily under a fluorescence microscope. Discernible fluorescence was detected only in infected cells by using the specific MB H1. A nonspecific MB, which was not complementary to the viral RNA sequence, produced no visible fluorescence signal. This MB-based fluorescence assay enabled the direct counting of fluorescent cells and could achieve a detection limit of 1 PFU at 6 h postinfection, demonstrating a significant improvement in viral quantification over current infectivity assays.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Molecular detection of hepatitis delta virus in blood donors with RT-PCR

Abstract Background and Objective: Hepatitis delta virus is an imperfect virus with RNA and its activity depends on the presence of hepatitis B virus. This virus can lead to acute and chronic diseases in the liver. This study aimed to detect the hepatitis delta virus in blood donors with positive Hepatitis B Surface Antigens (HBsAg). Material and Methods: In this Study, 350 serum sa...

متن کامل

Combined immunomagnetic separation-molecular beacon-reverse transcription-PCR assay for detection of hepatitis A virus from environmental samples.

In this study, a molecular-beacon-based real-time reverse transcription (RT)-PCR assay was developed to detect the presence of hepatitis A virus (HAV) in environmental samples. A 125-bp, highly conserved 5' noncoding region of HAV was targeted. The sensitivity of the real-time RT-PCR assay was tested with 10-fold dilutions of viral RNA, and a detection limit of 1 PFU was obtained. The specifici...

متن کامل

Real-time nucleic acid sequence-based amplification assay for detection of hepatitis A virus.

A nucleic acid sequence-based amplification (NASBA) assay in combination with a molecular beacon was developed for the real-time detection and quantification of hepatitis A virus (HAV). A 202-bp, highly conserved 5' noncoding region of HAV was targeted. The sensitivity of the real-time NASBA assay was tested with 10-fold dilutions of viral RNA, and a detection limit of 1 PFU was obtained. The s...

متن کامل

Development of a Western Blot Assay for Detection of Antibodies against HSV Using Purified HSV Virions Prepared by Sucrose Density Gradient

Objective(s) Herpes simplex viruses (HSVs) have widespread and ubiquitous prevalence in the human population and they have received a great deal of attention due to the range of diseases, they caused as a result of an infection. It seems that the fast and reliable diagnostic methods are needed for detecting the herpes simplex virus type 1 (HSV1) antibodies especially in patients with HSV encep...

متن کامل

Rapid and highly sensitive qualitative real-time assay for detection of respiratory syncytial virus A and B using NASBA and molecular beacon technology.

The performance of a sensitive and specific qualitative respiratory syncytial virus (RSV) assay based on NASBA technology and real-time molecular beacon detection is presented. Very low detection limits for both RSV A and RSV B were determined: 95% detection hit-rate of 95 and 47 copies/input in isolation for RSV A and RSV B, respectively. RSV was detected in a wide variety of clinical samples ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Applied and environmental microbiology

دوره 74 7  شماره 

صفحات  -

تاریخ انتشار 2008