Reproducibility of a continuous ramp lower body negative pressure protocol for simulating hemorrhage

نویسندگان

  • Victoria L Kay
  • Caroline A Rickards
چکیده

Central hypovolemia elicited by application of lower body negative pressure (LBNP) has been used extensively to simulate hemorrhage in human subjects. Traditional LBNP protocols incorporate progressive steps in pressure held for specific time intervals. The aim of this study was to assess the reproducibility of applying continuous LBNP at a constant rate until presyncope to replicate actual bleeding. During two trials (≥4 weeks intervening), LBNP was applied at a rate of 3 mmHg/min in 18 healthy human subjects (12M; 6F) until the onset of presyncopal symptoms. Heart rate (HR), mean arterial pressure (MAP), stroke volume (SV), total peripheral resistance (TPR), mean middle and posterior cerebral artery velocities (MCAv, PCAv), and cerebral oxygen saturation (ScO2) were measured continuously. Time to presyncope (TTPS) and hemodynamic responses were compared between the two trials. TTPS (1649 ± 98 sec vs. 1690 ± 88 sec; P = 0.47 [t-test]; r = 0.77) and the subsequent magnitude of central hypovolemia (%Δ SV -54 ± 4% vs. -53 ± 4%; P = 0.55) were similar between trials. There were no statistically distinguishable differences at either baseline (P ≥ 0.17) or presyncope between trials for HR, MAP, TPR, mean MCAv, mean PCAv, or ScO2 (P ≥ 0.19). The rate of change from baseline to presyncope for all hemodynamic responses was also similar between trials (P ≥ 0.12). Continuous LBNP applied at a rate of 3 mmHg/min was reproducible in healthy human subjects, eliciting similar reductions in central blood volume and subsequent reflex hemodynamic responses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Human splanchnic and forearm vasoconstrictor responses to reductions of right atrial and aortic pressures.

Regional vascular responses to gradual reductions in right atrial pressure and aortic pressure were investigated in nine men. In each study, lower body negative pressure was applied in a ramp of —1 mm Hg/min for 40-50 minutes. During the range from control to —20 mm Hg, right atrial pressure (4 studies) fell from 4.2 mm Hg to —0.6 mm Hg; heart rate was slightly reduced (2 beats/min), and aortic...

متن کامل

The Efficacy of a Protocolized Nursing Care on Nasal Skin Breakdown in Preterm Neonates Receiving Nasal Continuous Positive Airway Pressure

Background: Nasal continuous positive airway pressure (NCPAP) is an effective method of ventilation in newborns with respiratory distress syndrome (RDS). Using an appropriate nasal skin care protocol is identical to prevention or reduction of nasal skin breakdown in those who receive NCPAP. This study aimed to investigate the effectiveness of an evidence-based clinical care protocol on nasal sk...

متن کامل

Invited Review Lower body negative pressure as a model to study progression to acute hemorrhagic shock in humans

Cooke, William H., Kathy L. Ryan, and Victor A. Convertino. Lower body negative pressure as a model to study progression to acute hemorrhagic shock in humans. J Appl Physiol 96: 1249–1261, 2004; 10.1152/japplphysiol.01155.2003.— Hemorrhage is a leading cause of death in both civilian and battlefield trauma. Survival rates increase when victims requiring immediate intervention are correctly iden...

متن کامل

Non-linear Heart Rate and Blood Pressure Interaction in Response to Lower-Body Negative Pressure

Early detection of hemorrhage remains an open problem. In this regard, blood pressure has been an ineffective measure of blood loss due to numerous compensatory mechanisms sustaining arterial blood pressure homeostasis. Here, we investigate the feasibility of causality detection in the heart rate and blood pressure interaction, a closed-loop control system, for early detection of hemorrhage. Th...

متن کامل

Reductions in central venous pressure by lower body negative pressure or blood loss elicit similar hemodynamic responses.

The purpose of this study was to compare hemodynamic and blood analyte responses to reduced central venous pressure (CVP) and pulse pressure (PP) elicited during graded lower body negative pressure (LBNP) to those observed during graded blood loss (BL) in conscious humans. We hypothesized that the stimulus-response relationships of CVP and PP to hemodynamic responses during LBNP would mimic tho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2015