Development of a new thoron progeny detector based on SSNTD and the collection by an electric field.

نویسندگان

  • L Bi
  • J Tschiersch
  • O Meisenberg
  • M Wielunski
  • J L Li
  • B Shang
چکیده

The importance of (220)Rn (thoron) progeny for human exposure has been widely recognised in the past decades. Since no stable equilibrium factor was found between indoor thoron and its progeny, and the concentration of thoron progeny varies with time, it is necessary to develop detectors for long-term measurement that directly sample and detect thoron progeny. However, power supply of this kind of detectors has always been a problem. In this study, a set of device that is suitable for long-term measurement is introduced. A high-voltage electric field was formed for the collection of charged aerosols attached by (222)Rn (radon) and thoron progenies on solid-state nuclear track detector. Impact from radon progeny could be eliminated with a shield of Al foil of appropriate thickness. Tests were made both in an experimental house and in a thoron chamber in Helmholtz Zentrum München to determine the parameters and to verify the universality under different conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calibration and optimization of a low cost diffusion chamber for passive separated measurements of radon and thoron in soil by Lexan PC SSNTD

Background: Separate radon and thoron measurements in soil are very important in assessment of internal exposure due to inhalation of such radioactive gases. Materials and Methods: In this study, a low cost, small size, passive diffusion chamber has been developed for simple measurement of Radon-222 and Radon-220(Thoron) gases separately in soil. The diffusion chamber consists of two films and ...

متن کامل

Factors affecting the registration and counting of alpha tracks in solid state nuclear track detectors

In view of the fact that the radon progeny contribute the highest to the natural radiation dose to general populations, large scale and long-term measurements of radon and its progeny in the houses have been receiving considerable attention. Solid State Nuclear Track Detector (SSNTD) based systems, being the best suited for large scale passive monitoring, have been widely used for the radon gas...

متن کامل

A study of the polyethylene membrane used in diffusion chambers for radon gas concentration measurements

Solid-state nuclear track detectors (SSNTDs) in diffusion chambers have been routinely used for long-term measurements of radon gas concentrations. In usual practice, a filter is added across the top of the diffusion chamber to stop the progeny from entering. Thoron can also be deterred from entering the diffusion chamber by using a polyethylene (PE) membrane. However, the thickness of the PE m...

متن کامل

A study on radon and thoron progeny levels in dwellings in South India

Background: Decay products of radon and thoron present in indoor environment are the most important sources of radiation from natural sources which affect human beings, since general public spend at lest 80% of their time in indoor. Materials and Methods: Air samples were collected for measuring the concentration of radon and thoron daughter products from various indoor environments d...

متن کامل

A new thoron atmosphere reference measurement system.

A new thoron reference ((220)Rn) in air measurement system is developed at the LNE-LNHB with the collaboration of the IRSN. This measurement system is based on a reference volume with an alpha detector which is able to directly measure thoron and its decay products at atmospheric pressure. In order to improve the spectrum quality of the thoron progenies, we have applied an electric field to cat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 145 2-3  شماره 

صفحات  -

تاریخ انتشار 2011