Photodecomposition of o-phthaldialdehyde-derivatized amino acids by the photodiode array detector during their high-performance liquid chromatographic analysis.

نویسندگان

  • Sándor Kéki
  • János Török
  • Bernadett Biri
  • Judit Zsuga
  • Rudolf Gesztelyi
  • Dániel Bereczki
  • Miklós Zsuga
چکیده

During the high-performance liquid chromatographic (HPLC) analysis of o-phthaldialdehyde (OPA)-derivatized amino acids such as arginine and homoarginine, we observed that the response of the fluorescence detection (FLD) system is decreased when the photodiode array detection (DAD) system (located before the FLD system) was simultaneously switched on. The decrease in the FLD response, i.e., the difference in the FLD peak area (DeltaA) obtained with DAD modes off (A(off)) and on (A(on)) was dependent upon the flow rate, but the relative FLD response decrease (DeltaA/A(off)) was practically independent of the amount of analyte injected. For example, decreasing the flow rate from 1 to 0.5 mL/min resulted in the relative decrease of FLD response from approximately 5% to 11%. It was concluded that DAD caused a photoinduced partial decomposition of the OPA-derivatized amino acids flowing through the cell. The photoinduced dissociation of OPA derivatives was independently supported by using off-line photodiode array spectrometric measurements with long and short irradiation pulses. Based on the experimental results, for description of the variation of FLD responses with the flow rate upon the irradiation by DAD a simple mathematical model is proposed and reported.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of plasma amino acids by HPLC with photodiode array and fluorescence detection.

BACKGROUND Plasma amino acids are usually analyzed by ion-exchange chromatography (IEC), a reproducible but time consuming method. Here, we test whether plasma amino acids can be analyzed using reverse-phase high performance liquid chromatography (HPLC). METHODS Filtered plasma, with S-carboxymethyl-l-cysteine as the internal standard, was derivatized and analyzed by an Agilent 1100 HPLC syst...

متن کامل

Review: State-of-the-art of high-performance liquid chromatographic analysis of amino acids in physiological samples

Nowadays, the fast and sensitive high-performance liquid chromatographic I HPLC) analysis of derivatized amino acids is a good alternative to the ion-exchange chromatography (IEC) method for plasma amino acids. However, several precautions have to be taken in order to obtain reliable data on the concentration of amino acids in physiological fluids. These include the collection, centrifugation, ...

متن کامل

State-of-the-art of high-performance liquid chromatographic analysis of amino acids in physiological samples.

Nowadays, the fast and sensitive high-performance liquid chromatographic (HPLC) analysis of derivatized amino acids is a good alternative to the ion-exchange chromatography (IEC) method for plasma amino acids. However, several precautions have to be taken in order to obtain reliable data on the concentration of amino acids in physiological fluids. These include the collection, centrifugation, s...

متن کامل

HIGH-PERFORMANCE LIQUID CHROMATOGRAPHIC ANALYSIS OF SULFUR MUSTARD REACTION WITH AMINO ACIDS AND PROTEINS

The interaction of sulfur mustard with aminoacids and proteins has been investigated in this study. Rats were injected with sublethal doses of sulfur mustard subcutaneously and intraperitoneally. At different time intervals, plasma and urine samples were collected. The binding affinity of sulfur mustard with urinary and plasma proteins and enzymes was studied for the first time using non-i...

متن کامل

Photodiode array detection for liquid chromatographic profiling of carboxylic acids in physiological fluids: 3-hydroxy-3-methylglutaric aciduria.

3-Hydroxy-3-methylglutaric aciduria was detected in a newborn. The progress of the dietary therapy for the disorder was monitored by dual-column "high-performance" liquid chromatography with a computer-controlled photodiode array spectrophotometric detector. This procedure is a quick way to detect and monitor the progress of 3-hydroxy-3-methylglutaric aciduria.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatography. A

دوره 1185 2  شماره 

صفحات  -

تاریخ انتشار 2008